13
c.
Decommissioning
For storage, remove the load, lower the truck to the lowest position, grease all greasing points
mentioned in this handbook (regular inspection), and eventually protect the truck against corrosion and
dust. Remove the batteries and jack the truck safely, so that there will be no crush after storage.
For final decommissioning hand in the truck to a designated recycling company. Oil, batteries and
electric components must be recycled due to legal regulations.
5.
DAILY INSPECTION
This chapter describes pre-work checks before operating the truck.
Daily inspection is effective to find the malfunction or fault on this truck. Check the truck on the following
points before operation.
REMOVE LOAD FROM TRUCK AND LOWER THE FORKS.
DO NOT USE THE TRUCK IF ANY MALFUNCTION IS FOUND.
•
Check for scratches, deformation or cracks.
•
Check if there is any oil leakage from the cylinder.
•
Check the function of driving with tiller in its vertical position.
•
Check the chain and rollers for any damage or corrosion.
•
Check the smooth movement of the wheels.
•
Check the function of the emergency brake by activating the emergency button.
•
Check the functions of braking by activating the switches of the tiller.
•
Check the lifting and lowering functions by operating the buttons.
•
Check the horn.
•
Check if all bolts and nuts are tightened firmly.
•
Check the speed limit sensor.
•
Visual check if there are any broken oil pipes or electric wires.
•
If supplied with a load backrest, check it for damages and correct assembling.
6.
OPERATION INSTRUCTIONS
Fig.7: Tiller operating controls