11 

the  optional  canalization  kit  and  a  disassembly/

reassembly diagram for the decorative cover of 

the appliance.

This chapter also deals with non-standard 

installation options. Pipes which are not supplied 

with the product can still be purchased from your 

trusted dealer/service center.

The installation, disassembly and reassembly of the 

device must be carried out by qualified personnel 

authorized by Nobis Srl.

Please  note  that  having  the  device  opened/

disassembled  by  unauthorized  personnel  will 

invalidate the product warranty.

CONNECTION TO THE SMOKE EXHAUST SYSTEM

When  installing  the  first  section  of  the  flue  pipe, 

always remove the two upper diffusers to avoid 

damaging the paint.

First and foremost, unscrew the 4 screws highlighted 

on the back side and lift the two diffusers (held by 

magnets on the front).

Insert the first section of the flue pipe (

Ø130mm

). 

This must be of good quality and resistant to the 

high temperatures it could be subjected in the 

event of the opening of the safety bypass hatch.

Reassemble all the parts following the instructions 

in reverse.

WARNING: THE SECTION OF THE EXHAUST PIPE MUST 

WITHSTAND TEMPERATURES WHICH CAN EASILY 

REACH EVEN MORE THAN 600°C.

THE DEPRESSION OF THE SMOKE EXHAUST SYSTEM 

MUST RESPECT THE VALUE OF 12Pa.

ASSEMBLY OF THE CANALIZATION KIT (OPTIONAL) 

Remove the screws securing the upper left cover 

of the diffuser.

Remove the wooden cover (which is attached on 

the underside by means of magnets). Then unhook 

the side panel by unscrewing the two upper fixing 

screws. Remove it by lifting it from the lower screws 

(bayonet joint). Loosen the two screws holding the 

rear panel at the top (highlighted by the circles) 

and remove it.

Detach the pre-drilled sheet metal on the left or 

the one on the back, depending on the desired 

orientation of the canalization.

Fix  the  canalization  kit  using  the  5  screws 

(highlighted) already present in the stove. After 

properly securing the carter with the motor, plug in 

the electrical connection using the wiring already 

present in the device and already in place. Don't 

forget to activate the single pipe option in the 

user menu (via remote control).

Содержание UNICA 10 V/C

Страница 1: ...EN Installation use and maintenance manual WOOD UNICA 10 V C...

Страница 2: ...uctions manual can be reproduced or transmitted with any electronic or mechanical device including photocopying recording or any other saving system for any purpose other than the exclusive personal u...

Страница 3: ...7 1 RECEIVER 15 7 2 KEYS 16 7 3 DISPLAY 16 7 4 FLAT BATTERIES 16 7 5 ICON LIST WOOD 17 7 6 POWER MANAGEMENT 17 8 NAVIGATION MENU 17 9 START UP INSTRUCTIONS 17 9 1 DATE AND HOUR SETTINGS 17 9 2 ROOM PR...

Страница 4: ...indicated in this manual prompt execution of extraordinary maintenance if necessary malfunctioning activity and maintenance of safety devices do not remove or bypass this devices 1 3 IMPROPER USE The...

Страница 5: ...ng faulty due to negligence or careless use wrong maintenance non conforming installation with that specified by the manufacturer refer to the installation and use manual supplied with the appliance f...

Страница 6: ...the presence of forced ventilation or in premises which can go into negative pressure compared to outside 2 WOOD RECOMMENDED FEATURES For its products the Manufacturer recommends using class A1 or A1...

Страница 7: ...ostoves EN 14785 and 100 cm2 for boilers EN 303 5 The air intake is not necessary for installation of the hermetic appliances that take air directly from outside Check and comply with the ventilation...

Страница 8: ...ailable directly on the chimney flue plate 3 4 CHIMNEY STACK The standard UNI 10683 states the stack must meet the following features the smoke outlet section must be at least double the inner section...

Страница 9: ...is the case with concrete bricks etc wood composite materials etc In both cases make sure the passage for the flue pipe through the slab and the roof is wide enough to allow suitable safety distance 5...

Страница 10: ...he RESY standards and wooden pallets All packaging materials can be re used for similar use or if necessary disposed of as urban waste in compliance with legislation in force Remove the strap binding...

Страница 11: ...ould be subjected in the event of the opening of the safety bypass hatch Reassemble all the parts following the instructions in reverse WARNING THE SECTION OF THE EXHAUST PIPE MUST WITHSTAND TEMPERATU...

Страница 12: ...f the outer thermostat function refer to the specific chapter in the following pages of this manual It is compulsory for the system to be grounded and have a differential switch in compliance with leg...

Страница 13: ...0 S MATERIA PRIMA RAW MATERIAL A A B B C C D D E E F F 8 8 7 7 6 6 5 5 4 4 3 3 2 2 1 1 TUTTI GLI SVILUPPI FORNITI IN FORMATO DXF SONO TEORICI IL PARTICOLARE REALIZZATO DEVE ESSERE CONFORME AL DISEGNO...

Страница 14: ...rolonged not use of command risk of oxidation and liquid leakage Nobis srl declares that the type of Handheld radio device complies with Directive 2014 53 EU The full text of the EU declaration of con...

Страница 15: ...ust be enabled to allow the control unit to detect the presence of the external thermostat from the USER SETTINGS menu see the paragraph ENABLE EXTERNAL THERMOSTAT Enabling the external thermostat wil...

Страница 16: ...nds of inactivity the remote control display blacks out and switches to SLEEP mode maintaining the remote connection with the appliance Press to reactivate it This Icon indicates the appliance status...

Страница 17: ...led optional and enabled The menu is useful when you want to adjust the operating power to restart the appliance in pellet mode while Unica is running with wood 8 NAVIGATION MENU See the corresponding...

Страница 18: ...From the STAND BY screen press to activate power modification Values range from 1 to 3 They are represented by black boxes visible below room temperature Make changes by pressing Confirm the new setti...

Страница 19: ...ch subsequent load of wood the HOLD mode will be activated automatically This will maximize efficiency while minimizing emissions to the environment 9 7 COLD START Un Thanks to its flexibility Unica a...

Страница 20: ...he need to lower the lever bringing it back to its initial position thus closing the by pass Without electricity Unica requires the combustion air valve to be opened manually using the handle located...

Страница 21: ...th the only difference that it does not have 7 power levels but 3 plus PS which automatically follows the power set via remote control For further information see the same paragraph in the pellet mode...

Страница 22: ...rating anomaly press OK to display more details The stove has detected an alarm condition press OK to view more details Note by resolving the condition causing the alarm Unica will continue to operate...

Страница 23: ...ediately stop Unica in case of operation in pellet mode as for all the other Nobis products belonging to the pellet range Black Out with opening of the bypass hatch Safety thermal switch open door Pel...

Страница 24: ...SE SAFETY VACUUM SWITCH FRONT VENTILATION K J LAPTOP CONNECTION technical support only USB CONNECTION technical support only REMOTE CONTROL EMERGENCY CABLE APPLIANCE SWITCH ON REMOTE UNIT SELECTION KE...

Страница 25: ...Use and maintenance manual model UNICA 10 V C WOOD ENGLISH 25 MAINTENANCE DATE MAINTENANCE TASK PERFORMED...

Страница 26: ...Use and maintenance manual model UNICA 10 V C WOOD ENGLISH 26 MAINTENANCE DATE MAINTENANCE TASK PERFORMED...

Страница 27: ...Use and maintenance manual model UNICA 10 V C WOOD ENGLISH 27 MAINTENANCE DATE MAINTENANCE TASK PERFORMED...

Страница 28: ...o 11 25037 Pontoglio BS www nobisfire it Cod 110 002 0031N_S1 Nobis Srl cannot be held in any way liable for any errors in this manual and considers itself free to change the features of its products...

Отзывы: