Use and Maintenance Manual model “H17 V LIGHT”
22
ENGLISH
1
2
4
It shows power settings.
8.3 DESCRIPTION OF THE REMOTE CONTROL DISPLAY
The remote control display will appear as follows:
STAND-BY SCREEN
1
2
4
3
3
It shows boiler water actual temperature as detected
by the probe placed upstream in the system.
Moreover, temperature settings can be viewed by
pressing and then edited by pressing the two
scroll buttons
.
Any change in temperature settings is confirmed
either automatically - within 3 seconds from the last
change – or by pressing button. An acoustic
signal will confirm the change.
OK
From STAND-BY mode, press to get an overview of
the actual and active device status, as shown in the
following figure:
8.4 FLAT BATTERIES SIGNAL
If batteries are flat, the display will show a symbol indi
-
cating their limit status, maintaining the functions of the
remote control enabled anyway.
As soon as the battery level does not allow any remote
communication anymore, the remote control will dis-
play a full screen image of a flat battery, blocking all
other functions connected to it until the batteries are
replaced.
OK
Press to edit the appliance working power by
means of the scroll keys .
POWER
: it shows the appliance power, which can be
- MINIMUM: minimum editable power
- MAXIMUM: maximum editable power (see
specific section)
- ECO: product modulation when setting
values are reached;
- SANI: indicates dedicated power – in case
of need – if a rapid DHW kit is installed or else a parti-
cular system has been installed.
Each time the appliance is turned on, it always
activates at maximum power;
PUMP
: The word ‘ON’ indicates that the circulator is
active and is in the process of circulating water in the
house system.
3-WAY VALVE
: Indicates the positioning of any three-
way valve installed, if in the presence of a DHW
exchanger or a DHW tank.
PRESSURE
: Indicates the actual pressure of the
system read by the transducer, placed on the pro-
duct upstream.
After 20 seconds of inactivity, the display on the
remote control blacks out and passes to “SLEEP”
mode, maintaining the remote connection with the
appliance. The display will re-enable by simply by
pressing the
key.
Indicates the working power set. Moreover, by
pressing the scroll key
will allow temperature set-
tings to be displayed and then edited by using the
two scroll keys
.
Confirmation of each variation takes place
automatically within 3 seconds from the editing of
data, or by pressing the confirmation key. An
acoustic signal will confirm the change.
Icon indicating the status of the appliance
(see “Icons Overview”).
OK