Use and Maintenance Manual model “H17 V LIGHT”
20
ENGLISH
Select your standard language, using the keys .
Press
to confirm and move on to the next
screen.
To work properly, the remote control requires interfacing
with the electronic board inside the product.
For this reason, the display will show the following
installation message.
If this is the first use of the remote control, choose
YES
with the selection keys .Press to con-
firm and move on to the next screen.
Follow the instructions to link the appliance to the
display via remote, as showed in the figure below.
Keep the remote communication key of the
electronic board (placed on the rear of the product)
pressed for a few seconds to start the unit search
procedure.
The yellow, flashing led, under the icon indicates
that the electronic board is waiting for the remote
control signal.
Press the confirmation key
on the remote control
to make the components communicate with one
another.
A tick sign on the display, accompanied by an acoustic
signal, indicates that the remote connection operation
has been carried out successfully.
If the batteries are replaced, you don’t necessarily
have to follow the initialization procedure of the re-
mote control once again. In this case, when the dis-
play will show the message “FIRST INSTALLATION?”,
select
NO
and press the confirmation key .
OK
OK
OK
OK
7.3 PELLET LOADING
7.2 CONFIGURATION OF EXT. THERMOSTAT
TERMINAL
EXTERNAL THERMOSTAT
Fuel is loaded by opening the door and inserting
pellets from the upper part of the product. Please,
make sure that pellets contained in the bag do not
fall around the edges of the tank, paying particular
attention to centering while loading. Also, avoid the
packaging of the pellets to enter in contact with hot
surfaces.
If you want to manage the appliance from a different
room (i.e. where the remote control cannot commu-
nicate), you can connect an external thermostat to
the product, to adjust combustion or, by activating
a particular function, switch the product on/off. As
shown in the figure below, connect the terminals of
the thermostat to the terminal board on the back of
the product (near the emergency panel).
Once the electrical connection has been carried out,
it is necessary to activate the recognition function from
the SETTINGS menu to allow the control unit to recognize
the presence of the external thermostat (see paragraph:
“ENABLE EXTERNAL THERMOSTAT” ).
By enabling the function that enables the external thermo-
stat, reading and management of room temperature are
inhibited on the remote control. The remote control will dis-
plays TON when a higher temperature is required, TOFF if
the temperature set on the thermostat has been reached.
Make sure you close the cover of the tank properly
after loading pellets. Closure is controlled by an electronic
contact (when applicable). In case of failure to close, a
warning signal notifies the user to pay attention to closure.
A further alarm will be activated in case the warning is dis-