background image

NOBIS srl

Via Palazzolo N.11

25037 - Pontoglio - BS

www.nobisfire.it

 Cod. 110-002-0025N_S1

Nobis Srl cannot be held in any way 

liable for any errors in this manual 

and considers itself free to change the 

features of its products without prior 

warning.

Содержание H17 V LIGHT

Страница 1: ...EN Installation use and maintenance manual H17 V LIGHT...

Страница 2: ...oduct Please keep the manual in a suitable place after consulting it carefully Improper installation incorrect maintenance and or misuse of the product relieve the manufacturer of any liability toward...

Страница 3: ...oading 20 8 Description of remote control commands 21 8 1 Description of receiver 21 8 2 Description of remote control keys 21 8 3 Description of remote control display 22 8 4 Flat battery signalling...

Страница 4: ...regular basis do not remove or bypass this devices 1 3 IMPROPER USE The product is intended to be used for the purpos es and within the limits for which it was expressly de signed for any other use th...

Страница 5: ...nted chrome plated or gold plated parts handles and electrical cables lights switch resistor indicator lights knobs and all those parts that can be removed from the fireplace e g refractory brazier co...

Страница 6: ...able and reduce the overall efficiency of the system are created Hermetic products can also be installed in the presence of forced ventilation or in premises which can go into negative pressure if com...

Страница 7: ...ide not from other rooms garage etc and must have a net useful section equal or higher than 80 cm2 for pellet stoves and thermostoves EN 14785 and 100 cm2 for boilers EN 303 5 The air intake is not ne...

Страница 8: ...in the country of installation e g in Italy only roof discharge is permitted UNI 10683 standard states that the stack must meet the following characteristics the smoke outlet section must be at least...

Страница 9: ...lue with perforation for the passage of the piping increased of minimum 100mm around the pipe if in contact with inflammable parts such as cement bricks etc minimum 300mm around the pipe or as describ...

Страница 10: ...et cting it to the chimney flue By using the 4 adjustment feet find the right level so that the smoke discharge and the pipe are connected correctly Once the installation has been carried out the tech...

Страница 11: ...7 The door can be ope ned and closed to allow access to the emergency console 3 9 RIGHT FRONT PANEL ASSEMBLY fig 2 Take the left panel from the packaging and take it to vertical position to fix the 2...

Страница 12: ...hydraulic system of the product to the house system Product connection to the the house hydraulic system must be carried out exclusively by specialized personnel able to perform the installation to pe...

Страница 13: ...se before installing the appliance is para mount EXPANSION VESSEL In case of overheatinghe product is equipped with an expansion vessel to compensate for the increa se in water pressure inside the boi...

Страница 14: ...ermosifoni Valvola a tre vie Risc Sani Accumulo ACS Bollitore Flussostato ACS Valvola miscelatrice Accumulo acqua tecnica Puffer 11 12 13 14 15 16 17 18 19 8 4 EXAMPLES OF HYDRAULIC DIAGRAMS DIAGRAM 0...

Страница 15: ...a tre vie Risc Sani Accumulo ACS Bollitore Flussostato ACS Valvola miscelatrice Accumulo acqua tecnica Puffer 11 12 13 14 15 16 17 18 19 1 2 3 4 5 6 7 2 9 11 12 12 13 14 10 8 15 16 17 18 DIAGRAM 01 D...

Страница 16: ...ola a tre vie Risc Sani Accumulo ACS Bollitore Flussostato ACS Valvola miscelatrice Accumulo acqua tecnica Puffer 11 12 13 14 15 16 17 18 19 1 2 3 4 6 7 2 9 11 12 12 13 14 10 8 18 10 19 DIAGRAM 02 TEC...

Страница 17: ...to a parete Riscaldamento a pavimento Riscaldamento a termosifoni Valvola a tre vie Risc Sani Accumulo ACS Bollitore Flussostato ACS Valvola miscelatrice Accumulo acqua tecnica Puffer 6 7 8 15 16 17 D...

Страница 18: ...precautions all parts of the product must be cold ensure there is no form of combustion whatsoever for example hot ash use safety devices as per directive remove the plug from the electrical socket o...

Страница 19: ...radio device complies with Directive 2014 53 EU Full text of the EU declaration of conformity is available at the following Internet address https www nobisfire it wp content uploads 2019 04 DoC Palma...

Страница 20: ...F EXT THERMOSTAT TERMINAL EXTERNAL THERMOSTAT Fuel is loaded by opening the door and inserting pellets from the upper part of the product Please make sure that pellets contained in the bag do not fall...

Страница 21: ...pairing button 10 Manual upgrade button use by authorized staff ONLY Before connection using the emergency cable remove the batteries from the remote control FIRE HAZARD 1 3 2 4 5 6 7 8 9 10 1 2 3 4...

Страница 22: ...roll keys POWER it shows the appliance power which can be MINIMUM minimum editable power MAXIMUM maximum editable power see specific section ECO product modulation when setting values are reached SANI...

Страница 23: ...mptying ACTIVE COMFORT CLIMA RESTART FROM COMFORT CLIMA FINAL CLEANING OFF ALERT see specific paragraph FLAME OVERHEATING PELLET OVERLOAD 8 5 ICONS OVERVIEW 1 2 4 3 MEANING H2 O STANDBY FAULTY PRESSUR...

Страница 24: ...ATING PROCEDURE MENU USER SETTINGS PROBE ADJUSTMENTS Access user menu by pressing Scroll down entries to select SETTINGS using Access the menu by pressing OK OK By pressing scroll down entries to sele...

Страница 25: ...eration will be followed by acoustic signal and any alarms will be reset For models equipped with an automatic cleaner during the switch on phase the product activates a brazier cleaning phase before...

Страница 26: ...he temperature needed for the appliance to restart STATUS SCREEN To display the appliance shutdown on the display while in COMFORT CLIMA mode screen must be displayed To see that the appliance is abou...

Страница 27: ...hermostated so as to turn it off once the temperature in the room where the product is in stalled has been reached by means of the remote control and using only an external thermostat for the device e...

Страница 28: ...e is in the OFF or FINAL CLEANING status before activating this function The number expressed in seconds indicates the ro tation time of the auger during the loading phase After this time is up the au...

Страница 29: ...irm by pressing the key and move on to edit extraction OK To edit the extraction setting use keys The values vary from 5 reduction in extraction to 5 increase in extraction in Confirm by pressing and...

Страница 30: ...ce of a DHW storage tank with SUMMER settings OPERATING PROCEDURE MENU USER SETTINGS SEASON Access the menu by pressing Scroll down entries to select USER using Access the menu by pressing Scroll down...

Страница 31: ...STAND BY screen press repeatedly 12 10 ANTICONDENSATION exhaust fumes temperature This function ensures that the exhaust fumes temperature remains higher than condensate temperature OPERATING PROCEDUR...

Страница 32: ...ged by the appliance thanks to a contact or immersion probe not provided to be connected on the back side of the product The new stand by screen is shown below To return to the STAND BY screen press r...

Страница 33: ...heating by means of a con tact or immersion probe not provided always to be connected on the back of the product The new stand by screen is shown below STAND BY SCREEN 1 2 2 It shows the technical wa...

Страница 34: ...TING FOR FLAME FLAME PHASE RESTART PHASE DESCRIPTION Room temperature set on MAN mode In this case the appliance will operate only when the power of the combustion chamber has been set it NEVER switch...

Страница 35: ...t an authorized technician to solve the problem Anomaly to the upstream probe mo nitoring the water temperature in the technical water storage tank hot water tank please contact an authorized technici...

Страница 36: ...OWER SUPPLY No power supply or power supplied by the electronic control unit is inadequate SOLUTION If the problem persists contact the Support Service ALARM CODE REASON 11 MINIMUM PRESSURE PASCAL The...

Страница 37: ...M CODE REASON 29 CLEANING CYCLE LIMIT Maximum limit of cleaning cycles allowed during a prolonged working phase has been reached SOLUTION Vacuum the brazier in full safety and switch the product on ag...

Страница 38: ...way as to ensure easy access to the appliance itself and to the flue for cleaning and maintenance operations Lift the lever supplied with the product to unlock and open the door as illustrated in the...

Страница 39: ...asive effect avoiding the use of products with additives which could over time wear out seals glass and paint Do not switch on the appliance if the glass is damaged Contact the support service to repl...

Страница 40: ...ce intervention for proper operation are summarised below PARTS FREQUENCY TIME Ash pan approx time 7 DD Glass 2 3 DD Extraction pipe 1 SE Door seal ash pan 1 SE Tube bundle scraper where present 7 DD...

Страница 41: ...UAL RESET THERMAL SWITCH CONTACT DOOR ASH PAN 1 PELLET TANK 2 220V SOCKET WITH ON OFF SWITCH AND FUSE SAFETY VACUUM SWITCH FRONT VENTILATION PC CONNECTION technical support only USB CONNECTION technic...

Страница 42: ...Use and Maintenance Manual model H17 V LIGHT 42 ENGLISH DATE NOTE...

Страница 43: ...Use and Maintenance Manual model H17 V LIGHT 43 ENGLISH DATE NOTE...

Страница 44: ...N 11 25037 Pontoglio BS www nobisfire it Cod 110 002 0025N_S1 Nobis Srl cannot be held in any way liable for any errors in this manual and considers itself free to change the features of its products...

Отзывы: