24
User Settings
The UPS has setting functions. These user settings can be done under any kind of UPS working mode.
The setting will take effect under certain condition. Below table describes how to set the UPS.
Table 6.
User Settings
Setting function
Setting procedure
LCD display
ECO function
setting (1)
① Enter the setting interface. Press and hold the
function-setting key
for more than 2 seconds, then
come to setting interface, the letters “ECO” will
flash.
② Enter the ECO setting interface. Press and hold
the function-setting key
for more than half a
second (less than 2 seconds), the letters “ECO” will
stop flash. The “ON”(or OFF) below the ECO will
flash. Press and hold the scroll key
for more than
half a second (less than 2 seconds) to determine
whether the ECO function is enabled or disabled.
③ Confirm the ECO selecting interface. After
selecting ON or OFF, press and hold the function
setting key
for more than half a second (less than 2
seconds). Now, the ECO setting function is
completed and the “ON” or “OFF” below the
“ECO” will light without flash.
④ If you choose “OFF”, then go to step 7,
otherwise go ahead to step 5.
⑤ Set the ECO tolerance range. Short press the
scroll key
or for more than half a second (shorter
than 2 seconds) to select the voltage range in
percentage.
+5%,+10%,+15%,+25%(default
is
+25%),then short press function setting key
for
more than half a second (shorter than 2 seconds)to
confirm the selection, then to set the minus range
⑥ To set the minus range in the same way.
⑦ After the minus range is confirmed. Long press
function setting key
for more than 2 seconds to
exit setting menu.
Bypass function
setting (2)
① Enter the setting interface. Press and hold the
function setting key
for more than 2 seconds, then
come to setting interface, short press the scroll
key
for more than half a second (less than 2
seconds) to select BPS setting, the letters “bPS”
will flash.
②Enter the BPS setting interface. Press and hold the