![Nitta NITTAOMEGA L Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/nitta/nittaomega-l/nittaomega-l_instruction-manual_1696548031.webp)
5
.Procedures of Installation to Robot/Tool
23
Connecting to Fitting/Removal Port
Connect piping from the solenoid valve to the "CHUCK" port and "UNCHUCK" port of the
fitting/removal mechanism. The constant pressure line (with the valve not energized) must
always be connected with the "CHUCK" port to maintain coupling of the chuck/unchuck port
in the event of power failure.
Be sure to shut off the power supply, air, water and hydraulic power before
starting the work.
●Be careful to ensure tubes are connected to right ports (chuck port (CH) and
unchuck (UN) port). Otherwise the tool may fall off.
●Clearly mark the chuck (CH) and unchuck (UN) tubes accordingly.
●Securely insert the tubes to the end to prevent accidental
disconnection.
●There are two types of chuck/unchuck air piping: standard spec and solenoid
valve spec (a robot adaptor with solenoid valve).
●For the solenoid valve spec, there are one air supply port.
●Do not manually switch the air supply without an abs
olute need to do so.
Standard
Solenoid valve spec
Leave the "UNCHUCK" port opened without plugging even when
chuck/unchuck is not to be performed (in a coupled state only). Also, be sure to
pressurize the "CHUCK" port when using it. Otherwise, it may fall off.
About air piping for ATC driving:
ATC has a fail-safe mechanism to prevent the tool side from falling even when
air pressure is unexpectedly decreased. However, the air piping for ATC
driving requires proper selection and arrangement of solenoid valve to prevent
air from flowing into the "unchuck" side even when the valve is electrically
turned OFF.
- Do not use any three-position, closed-center type solenoid valve. The chucked
state cannot be maintained with the power supply turned OFF, which may
result in falling.
- Do not share an exhaust port with other equipment. Otherwise, the chucked
state cannot be maintained due to wrap-around back pressure, which may
result in falling.
- Do not branch the air supply to the "CHUCK" port to other equipment.
Otherwise, the chucked state cannot be maintained due to reduced pressure,
which may result in falling.
WARNING
WARNING
DANGER
Single tube
connection for
solenoid valve spec
Содержание NITTAOMEGA L
Страница 28: ...4 Part Names 20 4 Part Names Fig 3 Part names ...