7
Version date: March 27
th
2018
48
Operator Manual
NA 3338 Rapid Combi APM
7.3.14 (Dis)assembling, cleaning and disinfecting the mix pump
1. Pull
the locking pins
out of the pump.
2. Remove
the pump
foot from the pump.
3. Remove
the nozzle tu-
be.
4. Remove
the nozzle
from the tube.
5. Turn
the piston puller
in the piston.
6. Pull
the piston out of
the pump housing.
7. Remove
the piston
puller.
8. Loosen
the top disc
from the shaft.
9. Slide
the middle disc
from the shaft.
10.Remove
the O rings
from the outside of
the discs.
11.Remove
the O ring
from the shaft.
12.Remove
the two
O rings on the inside
of the middle disc.