“Default”
•
Reset the status of currently selected output device to the initial value.
•
The initial value depends on each device.
“Calibration”
•
Color correction value matching with the output device can be prepared.
•
Prepared color correction can be saved in the output device list under any name.
Calibration procedure
1. From the output device to be calibrated, output three sheets in total: gray chart
(Gchart.bmp), color chart 1 (Cchart1.bmp) and color chart 2 (Cchart2.bmp) stored in
chart folder (D: ¥chart¥)*1 within “NS-P1S/SU TWAIN” CD-ROM attached with this
device. Output size can be any of E., L, DSC, HV, KG/4R or Panorama among
“Photographs which can be scanned” on page 5. The output result must show 14 lines of
stripes for gray chart and 40 rectangles in total (8 vertically x 5 horizontally) for color
charts 1 and 2 as shown below:
*1: In this case, CD-ROM drive is set to D drive.
Gchart.bmp
Gray chart
Cchart1.bmp
Color chart 1
Cchart2.bmp
Color chart 2
25
P1SeManu220-Eng