For epidemic prevention and control emergency use only.
Production Certificate No.:20200170
Product Registration No.:20202071258
Executive Standard No.:GB/T 21417.1-2008

Manual of Medical Infrared Forehead Thermometer
Model:ZY-NIT-3

NINGBO HIGH-TECH ZONE ZHONGYE ELECTRONIC TECHNOLOGY CO., LTD
Thank you for purchasing this Infrared Forehead Thermometer. Please read the Instruction Manual carefully to make sure
safe and proper use of this thermometer.
Please read and fully understand the Safety Precautions before use.
Keep the Instruction Manual with this thermometer for future reference.
If the product has technical improvements, will be written into the new version of the manual, without further notice.

Product Information
Product Name:Medical Infrared Forehead Thermometer
Model:ZY-NIT-3

Unpacking Check
Please open the package carefully before use, check whether all accessories are available or not and whether any
component is damaged during transportation, and perform installation and operation following this user manual. In case
of any damage or operation problem, please contact the dealer or contact Zhongye directly. You will need the following
information when making your claim: device model, serial number, purchase date, and your contact information and
address.
Package Contents
No.

Name

Quantity

1

Infrared Forehead Thermometer

1

2

Screw 1.7x6

1

3

Instruction Manual

1

Safety Precautions
Read the following precautions carefully before using the thermometer.
Attention

Take care of the temperature probe lens, which is fragile.

Dispose used batteries with care. To protect the environment, you are recommended to send the used batteries to a

designated collection point.

Remove the batteries if the thermometer will not be used for more than two months.

Do not immerse the thermometer in water or expose it to direct sunlight.

Do not subject the thermometer to vibration or impact.

Do not take body thermometer readings within 20 minutes after you do physical exercises or get excited.

Do not use the thermometer for continuous temperature monitoring purposes.

Do not immerse the thermometer into water or other liquid. Clean and disinfect the thermometer as described in the

“Cleaning and Disinfection” chapter.

Do not touch the tip of the thermometer probe, on which a precise temperature sensor resides.

The ambient temperature must not be extremely high or low. To make sure accurate readings, keep the thermometer

under room temperature for more than 30 minutes before use.

Do not use the thermometer under an ambient temperature higher than 40

(104F) or lower than 10

(50F), which is

beyond the operating temperature range of the thermometer.

Содержание ZY-NIT-3

Страница 1: ...rchase date and your contact information and address Package Contents No Name Quantity 1 Infrared Forehead Thermometer 1 2 Screw 1 7x6 1 3 Instruction Manual 1 Safety Precautions Read the following precautions carefully before using the thermometer Attention Take care of the temperature probe lens which is fragile Dispose used batteries with care To protect the environment you are recommended to s...

Страница 2: ... must be paid The action is prohibited Information about the manufacturer Date of manufacture Consult the instructions for use Waste electrical materials should be sent to a dedicated collection point for recycling Degree of protection against the ingress of water A personal injury or damage to thermometer may occur if the thermometer is not used correctly Inaccurate reading or damage to the therm...

Страница 3: ... non contact infrared forehead thermometer intended to obtain the body temperature from the forehead It may be used by medical professionals or by consumers in a home environment 5 Contraindications None Features 1 Good safety Passive infrared receiving technology Non contact measurement preventing cross infection 2 Easy operation Handheld design easy operation One click automatic temperature meas...

Страница 4: ...lay and Operating Instructions Screen Display Operating Instruction Displayed State Description Measuring Forehead temperature In a power on state point the IR sensor to the center of the forehead Move the thermometer towards the forehead For effective measurement the distance between the thermometer and the forehead must be 1 2 to 2 1 5 cm Press and release the Measure button The forehead tempera...

Страница 5: ...ecall 50 memories Error information low battery Power off In any mode if there is no operation in 60 seconds the thermometer will power off automatically Measurement Process 1 Select the measurement mode Press the Measure button to power on the thermometer Select the measurement mode using the Mode button The symbol indicates the Forehead temperature mode The symbol indicates the Correction temper...

Страница 6: ...tteries of a same type should be used Dispose the used batteries in accordance with the local environmental policies Cleaning and Disinfection Cleaning Recommended detergents medical detergents Home use mild detergents Cleaning steps Take the batteries out before cleaning Clean the temperature with a soft cloth Clean the lens of the temperature probe with a cotton swab Wipe the thermometer body wi...

Страница 7: ...ctly The thermometer is damaged Contact the manufacturer Er1 is displayed The ambient temperature is lower than 10 50 or higher than 40 104 Take a measurement under an ambient temperature between 10 and 40 The thermometer is damaged Contact the manufacturer The temperature reading is lower than the typical body temperature range The lens of the temperature probe is dirty Clean the lens using a cot...

Страница 8: ...vents defibrillation charge effect No application parts of the thermometer output signal The thermometer is impermanent installed device Storage and Transportation Transportation The thermometer can be transported using general transportation tools Severe vibration shock or rain must be avoided during transportation Storage The thermometer must be packaged and then stored in a well ventilated room...