background image

In Forehead mode, a temperature
reading of more than 43.0

(109.4

)

A long beep and a green backlight for 3
seconds

Switching between

and

Press and hold the [SET] for 3 seconds
after switching on, and then switch the
temperature measurement unit
through [MEMO+] or [MEMO-]. The
display shows Celsius “

” or

Fahrenheit “

”, and then press [SET]

twice to exit. The default setting after
the first boot is Celsius

.

Silent

Switching between forehead temperature and MODE2 temperature

Switching between mute and un-mute

Recall 50 memories

Error information & low battery

Power-off
In any mode, if there is no operation in 60 seconds, the thermometer will power off automatically.

Measurement Process
1)Select the measurement mode.
Press the Measure button to power on the thermometer. Select the measurement mode using the Mode button.
The *

* symbol indicates the Forehead temperature mode. The *

* symbol indicates the Correction temperature mode.

2)Press the Measure button to start a measurement
When taking the forehead temperature, point the IR sensor to the center of the forehead. Move the thermometer towards
the forehead, the distance between the thermometer and the forehead must be 1/2” to 2” (1-5 cm). Press and release the

Содержание ZY-NIT-3

Страница 1: ...rchase date and your contact information and address Package Contents No Name Quantity 1 Infrared Forehead Thermometer 1 2 Screw 1 7x6 1 3 Instruction Manual 1 Safety Precautions Read the following precautions carefully before using the thermometer Attention Take care of the temperature probe lens which is fragile Dispose used batteries with care To protect the environment you are recommended to s...

Страница 2: ... must be paid The action is prohibited Information about the manufacturer Date of manufacture Consult the instructions for use Waste electrical materials should be sent to a dedicated collection point for recycling Degree of protection against the ingress of water A personal injury or damage to thermometer may occur if the thermometer is not used correctly Inaccurate reading or damage to the therm...

Страница 3: ... non contact infrared forehead thermometer intended to obtain the body temperature from the forehead It may be used by medical professionals or by consumers in a home environment 5 Contraindications None Features 1 Good safety Passive infrared receiving technology Non contact measurement preventing cross infection 2 Easy operation Handheld design easy operation One click automatic temperature meas...

Страница 4: ...lay and Operating Instructions Screen Display Operating Instruction Displayed State Description Measuring Forehead temperature In a power on state point the IR sensor to the center of the forehead Move the thermometer towards the forehead For effective measurement the distance between the thermometer and the forehead must be 1 2 to 2 1 5 cm Press and release the Measure button The forehead tempera...

Страница 5: ...ecall 50 memories Error information low battery Power off In any mode if there is no operation in 60 seconds the thermometer will power off automatically Measurement Process 1 Select the measurement mode Press the Measure button to power on the thermometer Select the measurement mode using the Mode button The symbol indicates the Forehead temperature mode The symbol indicates the Correction temper...

Страница 6: ...tteries of a same type should be used Dispose the used batteries in accordance with the local environmental policies Cleaning and Disinfection Cleaning Recommended detergents medical detergents Home use mild detergents Cleaning steps Take the batteries out before cleaning Clean the temperature with a soft cloth Clean the lens of the temperature probe with a cotton swab Wipe the thermometer body wi...

Страница 7: ...ctly The thermometer is damaged Contact the manufacturer Er1 is displayed The ambient temperature is lower than 10 50 or higher than 40 104 Take a measurement under an ambient temperature between 10 and 40 The thermometer is damaged Contact the manufacturer The temperature reading is lower than the typical body temperature range The lens of the temperature probe is dirty Clean the lens using a cot...

Страница 8: ...vents defibrillation charge effect No application parts of the thermometer output signal The thermometer is impermanent installed device Storage and Transportation Transportation The thermometer can be transported using general transportation tools Severe vibration shock or rain must be avoided during transportation Storage The thermometer must be packaged and then stored in a well ventilated room...