Problem
Possible cause
HOPPER AND RELEVANT DOOR
The hopper is lifted only 1-2 seconds after
turning on the control.
The operation is correct.
The hopper does not lift.
The distributor is stuck.
The push-button is cut off.
The operator is not on the driver’s seat.
The operator is on the driver’s seat but the hopper does not lift.
The input is not reaching the machine control board.
The output is not being provided by the display.
The operator is on the driver’s seat, the machine has stopped, but the hopper does not lift.
The machine is in neutral but the hopper does not lift.
All the safety requirements have been met but the hopper is not lifting.
The reverse gear buzzer sounds when pressing the lifting control.
The reverse gear buzzer does not turn on.
The output has not been delivered properly.
The output has been delivered properly.
The corresponding yellow LED does not turn off.
The yellow LED turns off.
The red LED does not turn off.
The LED will turn off properly when the machine control board issues the command.
The LED on the connector is off.
The LED on the connector is on.
SYSCODE.08
The lifted hopper microswitch is faulty or the lifting procedure is not correct.
The hopper lifts properly but the reverse
gear buzzer does not start.
The connections for lifting output are sent via diode D6 to the reverse gear buzzer too.
The buzzer is working when turning on other controls.
The buzzer does not turn on under any circumstances.
The fuse F15 is intact.
Relay K3 is operating properly.
The hopper does not return to horizontal
position/lower.
The cylinder gaskets are worn.
The engine speed is too low.
The distributor is stuck.
The operator is not on the driver’s seat.
The operator is on the driver’s seat but the hopper does not lower.
The reverse gear buzzer is turned on by pressing the push-button.
The reverse gear buzzer does not turn on.
The LED never turns off.
The LED turns out properly when using the joystick.
The red LED does not turn off.
The LED will turn off properly when the machine control board issues the command.
The LED on the connector is off.
The LED on the connector is on.
https://harrissupplyind.com - To Order Parts Call 608-268-8080