40 - Recovery System
92
Service Manual – SC250, Scrubtec 334, MA 30
Removal and Installation
Vacuum System Motor
Removal
1 Remove the tank assembly from the machine
2 Open the rear cover and remove the battery
3 Remove the screw to remove the controller protective cover
4 Disconnect the vacuum motor connections (A)
- Do not loosen the connection fastening screws, use a pair of pliers to hold the connector on the
controller
Figure 8
A
5 Remove the two cable retention clamps (B)
Figure 9
B
B