34 - Scrub System
73
Service Manual – SC250, Scrubtec 334, MA 30
Brush Motor (continues)
7 Remove the 7 caps (C) and remove the 7 screws (D), then remove the upper cover from the machine body
(E)
Figure 12
C
D
D
D
D
D
D
D
E
C
C
C
C
C
C
8 Remove the screw (F), keeping the inner locknut (G) held in position Remove the 2 screws (H), keeping
the inner locknuts (I) held in position
Figure 13
H
H
F
I
I
G
9 Working underneath the machine, remove the clamp (J) and extract the wiring Remove the motor and
transmission assembly (K) from the machine
Figure 14
J
K