30 - Solution System
58
Service Manual – SC250, Scrubtec 334, MA 30
Water Pump Voltage and Cleaning Check (continues)
Water Pump Cleaning/Unlocking
7 Blow in the Water pump duct (F) with the compressed air at 1 bar max (for the Water pump removal
see the procedure in Water pump removal/installation paragraph),
Caution! Blow with compressed air on the arrow direction as shown on the pump label.
8
Eventually instead dissambling the Water pump, blow the inlet on the solution filter compartment (G)
(use cloth to narrow the air flow).
Figure 8
F
G