34 - Scrub System
70
Service Manual – SC250, Scrubtec 334, MA 30
Removal and Installation
Driving Belt
Check
1 Remove the tank assembly from the machine
2 Open the rear cover and remove the battery
3 Remove the cylindrical brush
4 Remove the 4 screws (A) and remove the
protective casing on the transmission (B)
5 Visually inspect the entire length of the belt (C)
to make sure it is intact and shows no signs of
cuts, tears or cracks; replace if necessary
6 Check the tension of the belt (C) between motor
and brush using the TEN-SIT (D) device: When
deflecting the centre of the belt (E), the tool
should measure a value of 69Hz ±10
Belt tensioning
If necessary, tension the belt correctly (C)
7 Loosen the 3 screws (F) and adjust the position
of the motor and pulley (G) as necessary Once
the correct tension of the belt has been applied,
tighten the 3 screws (F)
Figure 7
A
A
A
A
B
C
D
E
Figure 8
C
F
F
F
F
G
F
F
G