70
- FORM NO. 56043122 - BR 1100S, 1300S
8 - ELECTRICAL SYSTEM
MAIN CONTROL PROGRAMMING OPTIONS
Fault Recall of Stored Error Codes:
Whenever the main control unit detects an electrical system fault, one or more error codes are displayed and stored by the control unit. If it is desired, the error code
(if any) from the previous operation of the machine can be recalled for troubleshooting purposes, To recall the last stored error codes perform the following steps:
1
Turn the main power switch to the off position.
2
Press and hold the solution switch.
3
While holding the solution switch, turn the main power key switch to the on position.
4
Continue to hold the solution switch until the solution indicator turns on.
5
Release the solution switch. A wrench icon will be displayed on the left top corner of the display indicating you are in fault recall mode.
6
If there were previously no error codes stored, the display will show the no-fault wrench icon asking you to reset the machine (no fault). Go to step
10.
7
If error codes were stored the display will show the wrench icon and error number(s) right next to the wrench. The scrub system off indicator will now blink. If
there is more than one error code stored. It will toggle through all the errors stored.
8
If it is desired to save the codes, go to step 10.
9
To clear the stored codes press the scrub off switch. The display will now show key switch icon asking you to reset the machine.
10 To exit the fault recall mode, turn the main power key switch to the off position.
Restoring the scrub pressure to factory default settings:
If it is desired to restore the scrub pressures to factory default setting, perform the following steps:
1
Turn the main power switch to the off position.
2
Press and hold the scrub-on switch.
3
While holding the scrub-on switch, turn the main power key switch to the on position.
4
Continue to hold the scrub-on switch until the display shows key switch icon.
5
The factory default pressures have now been restored.
6
Turn the main power key switch to the off position.
Fault Detection On or Off:
FACTORY DEFAULT: ON
Normally the main control unit will perform checks of the electrical system during operation. If a fault occurs in a particular system, that system (and possibly others)
will be shut down. This can make troubleshooting the system dif
fi
cult. This option will allow service personnel to disable some of the fault detection checks to facilitate
troubleshooting. This will not disable the over-current protection on any of the systems. To turn the fault checking on or off:
1
Turn the main power switch to the off position.
2
Press and hold the scrub-off switch and solution switch.
3
While holding both switches, turn the main power key switch to the on position.
4
Continue to hold both switches until both switch indicators turn on.
5
Release both switches. The display will now show a wrench icon in the upper left corner indicating fault protection mode. The solution indictor light will blink
and the scrub off will be turned on.
6
Pressing and releasing the solution switch will now select between fault’ detection enabled (wrench icon w/no cross) or disabled (wrench icon w/cross). Enabled
means that the fault checking is turned on, disabled means that the fault checking is turn off.
7
To save the setting, press the scrub off switch. The display will show the key switch icon asking the user to reset the machine.
8
The new setting will be saved and will remain in effect until it is changed again. Turn the key off to exit.
Содержание 56413006
Страница 7: ...FORM NO 56043122 BR 1100S 1300S 5 SPECIFICATIONS ...
Страница 9: ...FORM NO 56043122 BR 1100S 1300S 7 FIGURE 1 ...
Страница 10: ...8 FORM NO 56043122 BR 1100S 1300S THIS PAGE INTENTIONALLY BLANK ...
Страница 36: ...34 FORM NO 56043122 BR 1100S 1300S 4 RECOVERY SYSTEM FIGURE 4 2 ...
Страница 39: ...FORM NO 56043122 BR 1100S 1300S 37 SQUEEGEE SYSTEM 5 FIGURE 5 2 ...
Страница 47: ...FORM NO 56043122 BR 1100S 1300S 45 WHEEL DRIVE SYSTEM 6 FIGURE 6 5 ...
Страница 53: ...FORM NO 56043122 BR 1100S 1300S 51 REAR WHEEL SYSTEM 7 FIGURE 7 3 ...
Страница 61: ...FORM NO 56043122 BR 1100S 1300S 59 ELECTRICAL SYSTEM 8 J Ø 4 K Fault Indicator 03 FIGURE 8 7 ...