FORM NO. 56043122 - BR 1100S, 1300S -
73
ELECTRICAL SYSTEM - 8
MAIN CONTROL PROGRAMMING OPTIONS (CONTINUED)
Heavy Scrub Setting Adjustment:
FACTORY DEFAULT: SCRUB PRESSURE = TWO BAR, SOLUTION= TWO BAR, DETERGENT= 0 (IF AVAILABLE).
The heavy scrub pressure, solution rate and detergent rate can be programmed depending on its application where a higher solution rate is need with heavy scrub
pressure or low solution rate with heavy scrub pressure. To change all or any one setting, scrub, solution and detergent, perform the following steps:
1
Turn the main power switch to the off position.
2
Press and hold the scrub on and detergent switch.
3
While holding both switches, turn the main power key switch to the on position.
4
Continue to hold both switches until detergent switch indicators turns on and the heavy scrub blinks.
5
Release both switches. The display will now show a scrub icon (either disc or cylindrical) with the current scrub pressure setting. Scrub off indictor will turn on
and heavy scrub indicator will blink.
6
Pressing the scrub on switch will now select the new scrub pressure. Pressing scrub off switch will save the new setting and move to the solution rate setting.
7
The display will now show solution icon with gauge. Heavy scrub indicator will stop blinking and solution indicator will blink. Pressing solution switch will now
select solution rate. Pressing scrub off switch will save the new setting and move to detergent setting (if available).
8
The display will now show detergent bottle with current setting. Detergent indicator will blink. Pressing detergent switch will now select new detergent setting.
Pressing scrub off switch will save the new setting and display the key switch icon.
9
Then turn the key switch to the off position, the new settings will remain in effect until it is changed again.
Extreme Scrub Setting Adjustment:
FACTORY DEFAULT: SCRUB PRESSURE = THREE BAR, SOLUTION= THREE BAR, DETERGENT= 0 (IF AVAILABLE).
The extreme scrub pressure, solution rate and detergent rate can be programmed depending on its application where a higher solution rate is need with extreme
scrub pressure or low solution rate with extreme scrub pressure. To change all or any one setting, scrub, solution and detergent, perform the following steps:
1
Turn the main power switch to the off position.
2
Press and hold the scrub on and vacuum switch.
3
While holding both switches, turn the main power key switch to the on position.
4
Continue to hold both switches until vacuum switch indicators turns on and the extreme scrub blinks.
5
Release both switches. The display will now show a scrub icon (either disc or cylindrical) with the current scrub pressure setting. Scrub off indictor will turn on
and extreme scrub indicator will blink.
6
Pressing the scrub on switch will now select the new scrub pressure. Pressing scrub off switch will save the new setting and move to the solution rate setting.
7
The display will now show solution icon with gauge. Extreme scrub indicator will stop blinking and solution indicator will blink. Pressing solution switch will now
select solution rate. Pressing scrub off switch will save the new setting and move to detergent setting (if available).
8
The display will now show detergent bottle with current setting. Detergent indicator will blink. Pressing detergent switch will now select new detergent setting.
Pressing scrub off switch will save the new setting and display the key switch icon.
9
Then turn the key switch to the off position, the new settings will remain in effect until it is changed again.
Содержание 56413006
Страница 7: ...FORM NO 56043122 BR 1100S 1300S 5 SPECIFICATIONS ...
Страница 9: ...FORM NO 56043122 BR 1100S 1300S 7 FIGURE 1 ...
Страница 10: ...8 FORM NO 56043122 BR 1100S 1300S THIS PAGE INTENTIONALLY BLANK ...
Страница 36: ...34 FORM NO 56043122 BR 1100S 1300S 4 RECOVERY SYSTEM FIGURE 4 2 ...
Страница 39: ...FORM NO 56043122 BR 1100S 1300S 37 SQUEEGEE SYSTEM 5 FIGURE 5 2 ...
Страница 47: ...FORM NO 56043122 BR 1100S 1300S 45 WHEEL DRIVE SYSTEM 6 FIGURE 6 5 ...
Страница 53: ...FORM NO 56043122 BR 1100S 1300S 51 REAR WHEEL SYSTEM 7 FIGURE 7 3 ...
Страница 61: ...FORM NO 56043122 BR 1100S 1300S 59 ELECTRICAL SYSTEM 8 J Ø 4 K Fault Indicator 03 FIGURE 8 7 ...