background image

Grounding:

This machine must be grounded while in use to protect the operator from electrical shock.  The
machine is equipped with an approved three-conductor cord and three-prong grounding type
plug to fit the proper grounding receptacle.  The green (or green and yellow) conductor in the
cord is the grounding wire.  Never connect the green (or green and yellow) wire to a live ter-
minal.

Warning:

Never operate a machine that is not properly grounded.

If it is for use on 150 to 250 volts, it has a plug like that shown in Figure D.

An adapter, Figures B & C, is available for connecting Figure A plugs to two-plug receptacles.
The green-colored rigid ear, plug etc., must be connected to a permanent ground, such as a
properly grounded outlet box.  No adapter is available for a plug as shown in Figure D.
Adapter shown in Figures B & C is not for use in Canada.

Motor: 

This machine is powered by a 1 HP (model E) or 1.5 HP (model F) AC motor.  Be sure your
power supply agrees with the voltage marked on nameplates.  Incorrect voltage will cause the
motor to draw excessive current resulting in motor burn-out or blown fuse or circuit breaker.

Extension Cords:

Machines that have 3 wire cords requiring grounding must only be used with extension cords
that have 3-prong grounding type plugs and 3-pole receptacles.  Use only three-wire exten-
sion cord.  

To determine the minimum wire size required, refer to the chart below:

Chart for minimum wire size (AWG) of extension cord 
Nameplate

Total Extension Cord Length - Feet

Before using an extension cord, inspect it for loose or exposed wires, damaged insulation and
defective plugs.

CAUTION:

Always disconnect power cable from electrical outlet before working
on this machine.

PHC17F, PHC20F 

Floor Machines

This 

floor

machine is a high
q u a l i t y,  precision

made product.  All parts used in manufacturing this floor
machine have passed rigid quality control standards prior to
assembly and an “each unit” final inspection prior to packag-
ing is your assurance of proper assembly. This floor machine
is protectively packed to prevent possible damage in transit.
Should damage have occurred, please file a claim emmediat-
ly with the carrier who delivered the product to you.  You must
file the freight damage claim.  We, as the shipper, cannot do
this for you.

SAVE THESE INSTRUCTIONS

IMPORTANT SAFEGUARDS:

CAUTION:

Service  and  repair  should  be  performed  only  by  a  qualified  technician. 
Call 1-800-237-7582 for the location of your nearest Authorized Service 

Center.

OPERATION & CARE 

INSTRUCTIONS

Rating -
Amps

0-10.0

10.1-13.0
13.1-15.0

25

18
16
12

50

18
16
12

75

16
14
12

100

16
14
12

125

14
14
12

150

14
12
12

175

12
12
12

200

12
12

PHC

Содержание PHC17F

Страница 1: ...nsion cords that have 3 prong grounding type plugs and 3 pole receptacles Use only three wire exten sion cord To determine the minimum wire size required refer to the chart below Chart for minimum wire size AWG of extension cord Nameplate Total Extension Cord Length Feet Before using an extension cord inspect it for loose or exposed wires damaged insulation and defective plugs CAUTION Always disco...

Страница 2: ...le slightly The higher the handle is raised the faster the machine will move to the right Conversely to guide left lower the handle The more the handle is lowered the faster the machine will move to the left WARNING DO NOT LEAVE A PLUGGED IN MACHINE UNATTENDED Care and Maintenance This machine will afford you many years of trouble free service provided it is given proper care Throwing dropping bum...

Страница 3: ...la maquina encima de un banco o en el piso Alineando la manija con el centro de la abrazadera coloque el mango encima de la abrazadera con la calcomania hacia el frente Empuje el tuvo de el mango a traves de la abrazadera y colo quelo en la manija alineando los huecos de los tornillos Introduzca 2 tornillos de cabeza plana en los huecos del tubo y la manija haciendo esto de alante hacia atras de l...

Страница 4: ...box Terminal or uninsulated wire or stray wire strand in contact with machine frame handle pipe or switch box Machine underpowered for application EXAMPLE Using a 3 4 H P machine for carpet scrubbing Undersized extension cord Low electrical supply voltage CORRECTION Fully engage plug with outlet receptacle Replace fuse or reset circuit breaker Reset circuit breaker Replace with proper 3 wire cord ...