INC
JAA79551-R.3690.A
- A37 ・ AF-S VR 70-300/4.5-5.6G -
�
Make this inspection on both focal length 70mm (W) and 300mm (T).
�
If the lens stops while inspecting the lens-servo stop accuracy, input a figure in "Delay time" of the
below "Fig.3", from "0" to "1000" for the delay time (msec: millisecond) which prevents stopping
the lens.
Fig.3
(3) Inspection of lens-servo stop accuracy
Note:
The value of "ADUST DELAY-TIME" is set by the adjustment software. So, if the lens does not
stop during the inspection of "LENS DRIVING STOP ACCURACY", any value can be input without
problem.
However, the larger the value of "ADJUST DELAY-TIME" gets, the longer the inspection time becomes.
input box
Select the focal length
to be inspected.