INC
JAA79551-R.3690.A
- A 3・AF-S VR 70-300/4.5-5.6G -
CH1
CH2
④
In case the amplitude is small, loosen the two screws (#541)
that attach the GMR unit, and adjust the mounting angle of
the GMR unit.
⑤
In case the adjustment cannot be made in
④
, check the
MR head. If it is deformed, make a bending correction
for the MR head. If the correction is impossible or there
is no deform, replace the GMR unit. (Fig. 2)
Note: When adjustments are made, prevent the magnetic
surface and MR head from touching the magnetized
driver bit. Otherwise, the magnetic data may be
damaged.
#541×2
MR head
GMR unit
● Oscilloscope setting
V/Div (ch1)
: 50 mV
V/Div (ch2)
: 50 mV
Coupling
: AC
Time/Div
: 2 m Sec
Trigger Mode
: NORMAL
Trigger Coupling
: AC
Amplitude
Fig.1
Standard:
Amplitude of all pulses/wave-
forms is 80mV or more.
Note:
Check the waveform by moving the
focus ring back and forth from the
infinity-end to the close-end positions
entirely.
③
In case large waveform-noise (as shown in Fig. 1) is detected, use the FILTER function.
�ow to set FILTER function (e.g. DL1540 manufactured by YOKOGAWA
)
1. Press the FILTER button.
2. Select "Smooth" of the menu on screen and turn it ON.
Fig.2
Содержание JAA79551
Страница 97: ...INC JAA79551 R 3690 A A 70 AF S VR 70 300 4 5 5 6G Target chart Resolution chart ...
Страница 104: ...INC JAA79551 R 3690 A F AF S VR 70 300 4 5 5 6G 外観図 Sketch drawings ...
Страница 105: ...INC JAA79551 R 3690 A F AF S VR 70 300 4 5 5 6G 組立図 Structure of the Lens ...
Страница 106: ...INC JAA79551 R 3690 A F AF S VR 70 300 4 5 5 6G ...
Страница 107: ...INC JAA79551 R 3690 A F AF S VR 70 300 4 5 5 6G ...
Страница 108: ...INC JAA79551 R 3690 A F AF S VR 70 300 4 5 5 6G ...
Страница 109: ...INC JAA79551 R 3690 A F AF S VR 70 300 4 5 5 6G ...
Страница 110: ...INC JAA79551 R 3690 A F AF S VR 70 300 4 5 5 6G ...
Страница 111: ...INC JAA79551 R 3690 A F AF S VR 70 300 4 5 5 6G ...