EN nv
Niko
sa Industriepark West 40, BE-9100 Sint-Niklaas, Belgium — tel. +32 3 778 90 00 — fax +32 3 777 71 20 — e-mail: [email protected] — www.niko.eu
10-850
10-850
48
nv
Niko
sa Industriepark West 40, BE-9100 Sint-Niklaas, Belgium — tel. +32 3 778 90 00 — fax +32 3 777 71 20 — e-mail: [email protected] — www.niko.eu EN
Read the complete user manual before carrying out the installation and activating the system. Keep the manual for future reference.
1. DESCRIPTION
This telephone interface allows the connection of a Niko access control installation to the analogue telephone network. If you connect the telephone
interface to a telephone exchange, you can answer a door call, open the door or operate the relay …
You can program and/or edit a call list consisting of 4, 16, 32 or 64 call numbers, each with a maximum of 16 digits. Upon delivery, the telephone
interface contains a call list of 16 call numbers.
2. CONTROL KEYS AND STATUS LEDS
2.1. Control keys
See figure 1.
u
RESET key (key 2)
v
REPROG key (key 4)
Both of these keys are used to return the telephone interface to the factory settings (see section 5.23.).
2.2. Status LEDs
See figure 1.
w
red status LED indicates the status of the bus connection
x
yellow status LED indicates the status of the telephone connection
LED
Status
Meaning
off
resting mode
on
speech connection between bus and telephone installation
flashes slowly
busy: speech connection, alarm, notification
flashes quickly
error message: the a conductor is not connected or is not receiving
any power
1
switches off
telephone interface is activated for programming
switches on
door call, internal call or signal received from sensor
switches on once, long pause
error message: the a and P conductors are switched or have
short-circuited
1
switches on twice, long pause
error message: the same telephone interface number and different
versions of the telephone interface
1
switches on three times, long pause
error message: the same telephone interface number and identical
versions of the telephone interface
1
off
error message: the P conductor is not connected or is not receiving
any power
1
on, briefly
as long as the telephone interface is receiving a call signal
on
after a door call, while making a connection and during a speech
connection
flashes slowly
programming mode activated
flashes quickly, once
connection with telephone not possible, busy
switches off
after a door call with call diversion until the end of the time delay
switches on
connection to sensor
switches on once, long pause
variant with 16 call numbers
switches on twice, long pause
variant with 4 call numbers
switches on three times, long pause
variant with 32 or 64 call numbers
1
Consult section 7 for more information about error messages.