www.usmotors.com
ID300/302 Integrated Motor Drive |
Quick Start Commissioning
35
5.1.2 How to Read or Edit Parameters
By default, only the first 10 parameters of
0 Menu
are available. For
0 Menu
parameter access, set Pr
00.010 to Level 2. FOR advanced parameter access, set
Pr 00.010
to All Menus.
•
Parameter values affect the motor protection and the safety of the system.
DO NOT
change
parameter values without careful consideration. Incorrect values may cause damage to the unit or
a safety hazard.
• Be aware that some parameters are factory-set and should not be changed. For more details,
refer to Section 5.1.5 Restoring Parameter Defaults on
page 36
.
Power-up the ID300/302 and keep the drive disabled during the setting of parameters (Terminal 8 or
Terminals 31 & 34 open). Parameters can then be adjusted for the needs of the application. All
0 Menu
parameters are listed in Section 5.4 on
page 38
.
5.1.3 Navigation and Menu Structure
The drive parameter structure consists of menus (0 to 22) and parameters.
The drive initially powers up so that only the first 10 parameters of
0 Menu c
an be viewed. The left and
right navigation buttons can only be used to move between menus, if
Pr 00.010
has been set to show
‘All Menus’.
WARNING
!
Status
Mode
Ready
00.009
0.0 Hz
0.0 Hz
00.0001
0.0 Hz
00.0001
0.0 Hz
00.001
0.0
(Display
not
flashing)
To enter Parameter Mode
Press key or
Timeout
or
Press key
To return to Status Mode,
Press key
Timeout
Timeout
To select parameter
Press
To enter Edit Mode,
Press key
RO
parameter
R/W
parameter
(Character to be edited in lower line of display flashing).
Change parameter values using keys
keys to select
another parameter
to change,
if required
When returning
to Parameter Mode
use the
To return to Parameter Mode,
Press key to keep the new parameter value
Press key tp ignore the new parameter value and return
the parameter to the pre-edited value
Temporary
Parameter
Mode
(Upper display
flashing)
Edit Mode
Parameter
Mode
(Upper row