www.usmotors.com
26
ID300/302 Integrated Motor Drive |
Connections
Notes:
• The mains current value is a typical value which depends on the source impedance. The higher
the impedance, the lower the current.
• By default, the switching frequency is set to 3 kHz.
• ID300/302 are suitable for use on a circuit with a short circuit capability of not more than 5000 rms
symmetrical Amperes, 480V or 230V maximum when protected by fuses as specified above.
Mains
Supply
Max Input
Current (A) ID300K Ref
Fuse Ratings
Cable Size
CEI
UL
mm
2
AWG
230V
1ph
4.5
12017
6
6
1
16
5.3
12024
6
6
8.1
12030
10
10
9.1
22035
16
15
1.5
12
12
22052
16
15
14.3
22057
16
15
10.2
32075
16
15
12.2
32087
16
15
2.5
10
12.2
32120
20
20
14.8
32155
20
20
Mains
Supply
Max Input
Current (A) ID300K Ref
Fuse Ratings
Cable Size
CEI
UL
mm
2
AWG
460V
3ph
1.6
14012
6
6
1.5
12
2.2
14015
6
6
2.9
14018
6
6
3.4
14021
6
6
3.5
14025
6
6
3.5
14030
6
6
3.9
14033
10
10
7
24042
10
10
7.5
24050
10
10
8
24070
16
15
2.5
10
9.5
24085
16
15
13
34119
20
20
16
34155
25
25
4
10