8. Commissioning
The commissioning
(taking up operation in accordance with the intended use)
of the
DynaGear
gear unit is
prohibited until it has been determined that the machine or plant complies with the provisions of the EU machine
directive.
Before commissioning check the correct attachment of the transmission parts.
Check the oil level
Do not deactivate monitoring and protection devices, not even during test operation.
With DynaGear gear units, the use of an aeration and ventilation filter is not provided for. In special
cases, with very high operating temperatures, an aeration and ventilation filter may help decrease the
temperature and avoid leakages in S1 operation. Please contact our product management in this
regard.
The first start-ups must be carried out without load and at low speeds, until it is ensured that all roller bearings,
bevel gears and shaft seals are wetted with oil, then increase speed to approx. 500 min
-1
After approx. 30 min. slowly increase speeds until operational speed is reached, running in time at idle
approximately 90 min.
During start-up and run-up pay attention to running noise and temperature development particularly at the
bearing points. In the case of unusual running noise, shut down machine and identify fault.
See Section 10: "Faults, causes and remedies."
Apparent leakage at the shaft seal rings
Grease emerging from the lubrication in the shaft seal rings is not an oil leak.
This is an
apparent leakage
, until the remaining lubricant has become regulated.
Wipe off apparent leakage and continue to observe.
Attention against damage to gear unit:
If the new gear unit is started up too quickly, the bearings may overheat,
and the tooth flanks may be insufficiently lubricated.
It is necessary to allow the gear unit to run-in in stages!
Warning
:
Risk of burns!
Possibility of severe burns on hot surfaces (>55°C).
Wear suitable gloves and protective clothing.
9. Operation of the DynaGear unit
9.1 General notes on operation
The instructions in Section 1 "General safety notes", Section 10 "Faults, causes and remedies",
and Section 11 "Inspection and maintenance" must be complied with.
In order to achieve a perfect trouble-free operation of the gear unit, the operating factors defined in the
"Technical Data" must be complied with.