![background image](http://html1.mh-extra.com/html/nidec/dynagear-d115/dynagear-d115_installation-and-operating-instructions-manual_1687858015.webp)
www.graessner.de
gmb / BA DynaGear_EN
Page 15 of 22
7.4 Installation of the other fitted components
The drive and output elements (gears, belt wheels, jointed shafts etc.):
▪
Must have been balanced with G 6.3
▪
Must only be fitted using suitable fitting and withdrawal devices
▪
Must be axially secured even if they have been shrunk on
When using suitable tensioning elements, the tightening torques must be considered
The components must be mounted onto the shaft as far as is specified in the article-related dimension sheet.
In the case of a belt drive the correct belt tension must be assured, comply with the manufacturer's instructions
in this regard. The permissible transversal forces for the shaft must not be exceeded (see catalogue).
Drive and output elements must be covered by contact protection
7.5 Finishing work
▪
Before fitting protective covers check again the correct oil level in the gear unit.
▪
Check for even running free from strains, stresses, and any faults.
▪
Fit protective covers.
▪
Carefully clear away all tools as well as any parts not fitted.
Attention
:
Due to
incorrect installation
the gear unit can be damaged and become
unusable. Such damage may be caused by falling objects, dumping, welding work
or insufficient attachment.
The operator must ensure:
▪
The gear unit must be protected against any falling objects and dumping
▪
Welding work must not be carried out on any part of the drive
▪
The gear unit must not be used as a ground point for electric welding work
▪
All mounting options assigned to the build type must be used.
▪
Any screws that have become unusable during assembly and disassembly must be
replaced by new ones featuring the same design and strength class.