SM-Applications Modules & Motion Processors User Guide
65
Issue Number: 4
S
Info
rm
In
Inst
al
Get
ting
Pa
ra
DP
L
P
C
Fre
eze
CT
Syn
Inter-o
S
Di
M
Q
In
This parameter will increment every time a CTSync message is received with a bad
checksum
This parameter will increment every time a message has not been received when the
module is expecting one.
This parameter will increment every time the synchronization signal is the incorrect
width. During synchronization this parameter is likely to increase but should stabilise
once synchronization is complete. After synchronization, if this parameter is
incrementing then there is likely to be excessive noise on the EIA-RS485 network.
Check the connections.
This parameter allows the user to set up the Second Processor in the Inter-Option
module Synchronization scheme. For more information refer to Chapter 10
Pr 91.18
Number of Bad CTSync Messages Received
Access
RW
Range
Signed 32-bit
Default
N/A
Update Rate
Apps
Apps Lite Apps Plus
Lite V2
ST Plus
ST Indexer
Pr 91.19
Number of Missing CTSync Messages
Access
RW
Range
Signed 32-bit
Default
N/A
Update Rate
Apps
Apps Lite Apps Plus
Lite V2
ST Plus
ST Indexer
Pr 91.20
CTSync Synchronization Signal Width too Short
Access
RW
Range
Signed 32-bit
Default
N/A
Update Rate
Synchronization
Apps
Apps Lite Apps Plus
Lite V2
ST Plus
ST Indexer
Pr 91.21
Inter-option Synchronization Control
Access
RW
Range
0 to 2
Default
0
Update Rate
Immediate
Bit
Description
0
Set this bit for the Second Processor to participate in the Inter-Option Module
Synchronization scheme as a Producer. Refer to section 10.1
page 104 for details of the term Producer.
1
Set this bit for the Second Processor to participate in the Inter-Option Module
Synchronization scheme as a Consumer. Refer to section 10.1
page 104 for details of the term Consumer.
Apps
Apps Lite Apps Plus
Lite V2
ST Plus
ST Indexer
Содержание Digitax ST Indexer
Страница 131: ......
Страница 132: ...0471 0062 04...