120
SM-Applications Modules & Motion Processors User Guide
Issue Number: 4
12.2.2 Menus 18/19
These menus remain unchanged.
12.2.3 Menu 20
•
Menu 20 now consists of 40 parameters rather than 50. Parameters Pr
20.21
to
Pr
20.40
are now full signed 32-bit parameters.
•
Previously the first 20 parameters of menu 20 were considered to be reserved for
communications options. This is now no longer the case since communications
parameters are set up in menu 15/16/17, therefore all of menu 20 is free for use.
•
The saving of menu 20 has also changed. In order to save the parameters you must
set parameter Pr
81.21
to a 1 and then set Pr
81.19
or Pr
81.20
. The reason for this
change is that you can now potentially have two or three SM-Applications Modules
& Motion Processors fitted into the drive and since menu 20 is saved and restored
from the flash memory of the module, only one module can be configured to look
after menu 20 otherwise it will be incorrectly restored.
12.2.4 PLC Registers
•
There are now an extra 200
saveable
registers available. These are in register
banks T and U (or menus 74 and 75). The P/Q/R/S register sets remain as they
were, however since there is no built-in position controller, the Q register set is
completely free for use.
•
On the UD70 with CTNet, some registers in the R and S sets were reserved. This is
no longer the case - all 100 registers of both sets can be used for CTNet cyclic data
links (note that 3 registers in R and S are still reserved for use with easy mode cyclic
data links).
12.2.5 Menu 90 Parameters
Substantial changes have occurred to parts of this menu and programs WILL have to be
modified to take them into account. The encoder position parameters Pr
90.01
/Pr
90.03
now provide the full position information (including fine position) scaled such that the full
32-bit value represents one revolution. Separate revolution counters are available in
Pr
90.02
and Pr
90.04
.
Pr
17.23
EVENT trigger control
See Pr
81.35
. This parameter is now CTNet ID.
Pr
17.24
ANSI 2-wire turn-around
See parameter Pr
81.08
. Parameter now used by
CTNet.
Pr
17.25
+ Unused
There are now 51 set-up parameters.
Table 12-1 Setup Parameter Changes
Parameter Description
Changes