108
SM-Applications Modules & Motion Processors User Guide
Issue Number: 4
The italicised Pr
91.22
is a status parameter and does not require setting. It shows
whether the module has achieved the Inter-Option functionality specified in Pr
91.21
.
For more information refer to Pr
91.12
.
Before setting the parameters above, the POS tasks may be executing out of phase
with each other as shown in Figure 10-3
POS Task Execution BEFORE Inter-option
. After setting the parameters to the values shown above
the POS tasks should be executing in phase with each other as shown in Figure 10-
4
POS Task Execution AFTER Inter-option Synchronization with CTSync
When a module is a CTSync Slave, it has to be the Inter-Option Synchronization
Producer on the drive it is fitted to therefore Pr
91.21
will automatically be set to a value
of 1.