52
SM-Applications Modules & Motion Processors User Guide
Issue Number: 4
Writing to this parameter updates the control word. Reading from this parameter reads
the status word (same as Pr
10.40
).
Pr 90.11
Drive Status and Control Word
Access
RW
Range
Signed 16-bit
Default
N/A
Update Rate
Immediate
Table 5-5 Control Word
Bit
Description
b15
If set, the value of Pr
01.46
is set from b6
b14
If set, the value of Pr
01.45
is set from b5
b13
Sets the value of Pr
18.33
(Application menu 1, bit 3)
b12
If set, the value of Pr
06.32
is set from b3
b11
If set, the value of Pr
06.31
is set from b2
b10
If set, the value of Pr
06.30
is set from b1
b9
If set, the value of Pr
06.15
is set from b0
b8
Sets the value of Pr
18.32
(Application menu 1, bit 2)
b7
Sets the value of Pr
18.31
(Application menu 1, bit 1)
b6
Sets the value of Pr
01.46
(Preset select bit 1)
b5
Sets the value of Pr
01.45
(Preset select bit 0)
b4
User trip. Trips drive immediately if set.
b3
Sets the value of Pr
06.32
(Sequencing bit 2: Run Reverse)
b2
Sets the value of Pr
06.31
(Sequencing bit 1: Jog)
b1
Sets the value of Pr
06.30
(Sequencing bit 0: Run forward)
b0
Sets the value of Pr
06.15
(Drive enable)
Table 5-6 Status Word
Bit
Description
b15
Not used
b14
Pr
10.15
(Mains Loss)
b13
Pr
10.14
(Direction running)
b12
Pr
10.13
(Direction commanded)
b11
Pr
10.12
(Braking resistor alarm)
b10
Pr
10.11
(Braking IGBT active)
b9
Pr
10.10
(Regenerating)
b8
Pr
10.09
(Drive output is at current limit)
b7
Pr
10.08
(Load reached)
b6
Pr
10.07
(Above set speed)
b5
Pr
10.06
(At speed)
b4
Pr
10.05
(Below set speed)
b3
Pr
10.04
(Running at or below min speed)
b2
Pr
10.03
(Zero speed)
b1
Pr
10.02
(Drive running)
b0
Pr
10.01
(Drive healthy)