SM-Applications Modules & Motion Processors User Guide
35
Issue Number: 4
S
Info
rm
In
Inst
al
Get
ting
Pa
ra
DP
L
P
C
Fre
eze
CT
Syn
Inter-o
S
Di
M
Q
In
Defines the action taken if a user DPL program attempts to write an out of range value
to a parameter. When set at 1, a run-time trip will occur (number 44); when set at zero
the value will automatically be limited to the maximum/minimum of that parameter
When set it enables the DPL program watchdog function. The DPL WDOG command
must then be executed every 200 ms. This can be used to protect the program against
malfunction. If the command is not executed within a 200 ms time period the drive will
trip on
SLx.tO
. Please note that the WDOG command must also be executed once for
the watchdog to be enabled. This is normally executed at the end of the Initial task.
Pr 81.16
Encoder Data Update Rate
Access
RW
Range
0-3
Default
0
Update Rate
Initialization
Display
Description
0
APC data and menu 90 encoder parameters are
updated every 250 µs.
1
APC data and menu 90 encoder parameters are
updated immediately prior to every POS task.
2
APC data and menu 90 encoder parameters are
updated immediately prior to every CLOCK task.
3
APC data and menu 90 encoder parameters are
never updated. If these are never updated, more
processor resource will become free.
Apps
Apps Lite Apps Plus
Lite V2
ST Plus
ST Indexer
Pr 81.17
Enable Parameter Over-range Trips
Access
RW
Range
0/1
Default
0
Update Rate
Initialization
Apps
Apps Lite Apps Plus
Lite V2
ST Plus
ST Indexer
Pr 81.18
Watchdog Enable
Access
RW
Range
0/1
Default
0
Update Rate
Initialization
Apps
Apps Lite Apps Plus
Lite V2
ST Plus
ST Indexer
Содержание Digitax ST Indexer