SM-Applications Modules & Motion Processors User Guide
117
Issue Number: 4
S
Info
rm
In
Inst
al
G
Pa
ra
DP
L
Pr
Communica
F
CT
Sy
nc
In
Sy
nc
Dia
gnos
Mi
Q
Ind
ex
This parameter shows the peak that parameter Pr
88.04
reaches. It will show the lowest
value that parameter Pr
88.04
reaches since the monitoring was enabled (Pr
88.03
). It
will give a realistic indication of the worst case available resources for the motion engine
tasks so that the user can see how close the module has been to a motion engine task
overrun.
This parameter allows the user to enable or disable monitoring of the CLOCK task free
resource. When set to 1, parameters Pr
88.07
and Pr
88.08
become active. If set to
zero, parameters Pr
88.07
and Pr
88.08
will read zero
This parameter indicates the percentage resource available for running the Clock task. If
this parameter value reaches zero a task overrun will occur. It is calculated every Clock
period and is displayed for the previous motion engine period.
This parameter shows the peak that parameter Pr
88.07
reaches. It will show the lowest
value that parameter Pr
88.07
reaches since the monitoring was enabled (Pr
88.06
). It
will give a realistic indication of the worst case available resources for the Clock task so
that the user can see how close the module has been to a Clock task overrun.
Pr 88.05
Motion Engine Peak Resource Detect
Access
RW
Range
0 to 95
Default
0
Update Rate
See Pr
88.04
Apps
Apps Lite Apps Plus
Lite V2
ST Plus
ST Indexer
Pr 88.06
CLOCK Task Resource Monitoring
Access
RO
Range
0/1
Default
NA
Update Rate
Immediate
Apps
Apps Lite Apps Plus
Lite V2
ST Plus
ST Indexer
Pr 88.07
Free Resource for Clock Task
Access
RO
Range
0 to 95
Default
NA
Update Rate
See Pr
81.11
Apps
Apps Lite Apps Plus
Lite V2
ST Plus
ST Indexer
Pr 88.08
Clock Task Peak Resource Detect
Access
RO
Range
0 to 95
Default
NA
Update Rate
See Pr
81.11
Apps
Apps Lite Apps Plus
Lite V2
ST Plus
ST Indexer
Содержание Digitax ST Indexer