96
Digitax HD M75X Series Installation and Technical Guide
Issue Number: 5
Figure 5-13 Layout output current, speed and power profile
on page 10, the drives listed in
Table 5-7 meet the individual power and current profiles for each axis.
The total peak power demanded from the multi axis system is 9.6 kW, with reference to
the maximum continuous AC input power of the M753-03400160 selected for axis 4.
The total DC bus capacitance for all drives selected is 980
application example. The maximum frame block capacitance for an
M753-03400160 with no line reactor is 2210
The M753-03400160 can therefore be used as the AC source with all drives connected as one frame block via a parallel DC bus.
As the AC input current remains within 40 A and no supplemental DC fuses are required, three 40 A LPJ fuses in the AC branch would be sufficient.
Table 5-7 Application example
Axis name
Motor current
Output power
Internal capacitance
A
kW
F
Axis A - M753-01400042
0 to 12.6
0 to 6.69
110
Axis B - M753-01400042
0 to 12.6
-6.69 to 0
110
Axis C - M753-02400105
5 to 25
-0.8 to 8.7
290
Axis D - M753-03400160
0 to 40
0.0 to 4.28
470
Total capacitance = 980
F
3
4
5
1
2
Optional
EMC filter
Axis D
Axis C
Axis B
Axis A
0
5
10
15
20
25
30
35
40
45
0
0.5
1
1.5
2
2.5
3
Curr
en
t (A)
Time (s)
Current vs Time
Axis A
Axis B
Axis C
Axis D
-60
-40
-20
0
20
40
60
0
0.5
1
1.5
2
2.5
3
Speed (Hz)
Time (s)
Speed vs Time
Axis A
Axis B
Axis C
Axis D
-8
-6
-4
-2
0
2
4
6
8
10
12
0
0.5
1
1.5
2
2.5
3
P
o
w
er (kW)
Time (s)
Power vs Time
Axis A
Axis B
Axis C
Axis D
Total Power
Содержание Digitax HD M75 Series