Power drive systems are categorized C1 to C4:
Note that category 4 is more restrictive than E2R, since the rated current
of the PDS must exceed 400 A or the supply voltage exceed 1000 V, for
the complete PDS.
Key:
(shown in decreasing order of permitted emission level):
E2R EN 61800-3:2004+A1:2012 second environment, restricted
distribution
(Additional measures may be required to prevent interference)
E2U EN 61800-3:2004+A1:2012 second environment, unrestricted
distribution
I Industrial generic standard EN 61000-6-4:2007+A1:2011
EN 61800-3:2004+A1:2012 first environment restricted
distribution (The following caution is required by EN 61800-
3:2004+A1:2012)
R Residential generic standard EN 61000-6-3:2007+A1:2011
EN 61800-3:2004+A1:2012 first environment unrestricted
distribution
EN 61800-3:2004+A1:2012 defines the following:
• The first environment is one that includes residential premises. It also
includes establishments directly connected without intermediate
transformers to a low-voltage power supply network which supplies
buildings used for residential purposes.
• The second environment is one that includes all establishments other
than those directly connected to a low-voltage power supply network
which supplies buildings used for residential purposes.
• Restricted distribution is defined as a mode of sales distribution in
which the manufacturer restricts the supply of equipment to
suppliers,
customers or users who separately or jointly have technical competence
in the EMC requirements of the application of drives.
Category
Definition
Corresponding
code used
C1
Intended for use in the first or second
environments
R
C2
Not a plug-in or movable device, and
intended for use in the first environment
only when installed by a professional, or
in the second environment
I
C3
Intended for use in the second
environment, not the first environment
E2U
C4
Rated at over 1000 V or over 400 A,
intended for use in complex systems in
the second environment
E2R
This is a product of the restricted distribution class according
to IEC 61800-3. In a residential environment this product may
cause radio interference in which case the user may be
required to take adequate measures.
CAUTION