102
Digitax HD M75X Series Installation and Technical Guide
Issue Number: 5
Table 6-6 Open loop and RFC-A maximum permissible continuous output current @ 50 °C (122 °F) ambient
Table 6-7 Open loop and RFC-A maximum permissible continuous output current @ 50 °C (122 °F) ambient with rear duct fitted
Model
Heavy Duty
Maximum permissible continuous output current (A) allowing for 175 % overload for 4.5 s
2 kHz
3 kHz
4 kHz
6 kHz
8 kHz
12 kHz
16 kHz
200 V
01200022
2.2
2.2
2.2
2.2
2.2
2.2
2.2
01200040
4.0
4.0
4.0
4.0
4.0
4.0
4.0
01200065
6.2
6.1
5.9
5.7
5.4
4.9
4.4
02200090
9.0
9.0
9.0
9.0
9.0
9.0
9.0
02200120
11.5
11.3
11.0
10.7
10.3
9.8
9.5
03200160
16.0
16.0
16.0
16.0
15.7
14.0
13.3
400 V
01400015
1.5
1.5
1.5
1.5
1.5
1.5
1.5
01400030
3.0
3.0
3.0
3.0
3.0
2.9
2.5
01400042
3.5
3.4
3.4
3.3
3.2
2.9
2.5
02400060
6.0
6.0
6.0
6.0
6.0
6.0
5.4
02400080
8.0
8.0
8.0
8.0
7.5
6.5
5.4
02400105
9.1
9.0
8.9
8.2
7.5
6.5
5.4
03400135
13.5
13.5
13.5
13.3
12.2
9.9
8.2
03400160
16.0
15.2
14.6
13.3
12.2
9.9
8.2
Model
Heavy Duty
Maximum permissible continuous output current (A) allowing for 175 % overload for 4.5 s with rear duct fitted
2 kHz
3 kHz
4 kHz
6 kHz
8 kHz
12 kHz
16 kHz
200 V
01200022
2.2
2.2
2.2
2.2
2.2
2.2
2.2
01200040
3.8
3.8
3.7
3.5
3.3
3.1
2.7
01200065
3.8
3.8
3.7
3.5
3.3
3.1
2.7
02200090
9.0
9.0
8.9
8.5
8.3
7.9
7.6
02200120
9.2
9.0
8.9
8.5
8.3
7.9
7.6
03200160
14.7
14.6
14.4
14.0
13.1
11.8
11.0
400 V
01400015
1.5
1.5
1.5
1.5
1.5
1.5
1.5
01400030
2.1
2.0
1.9
1.8
1.7
1.7
1.7
01400042
2.1
2.0
1.9
1.8
1.7
1.7
1.7
02400060
6.0
6.0
6.0
6.0
6.0
5.6
4.6
02400080
8.0
8.0
8.0
7.4
6.6
5.6
4.6
02400105
9.2
8.7
8.2
7.4
6.6
5.6
4.6
03400135
12.5
12.3
12.2
11.2
10.2
8.3
6.7
03400160
12.5
12.3
12.2
11.2
10.2
8.3
6.7
Содержание Digitax HD M75 Series
Страница 115: ......
Страница 116: ...0478 0395 05...