8.3 Replacement Components 

Three replacement filters are provided with the illuminator. They should be kept in an 
accessible location. Replacement lamps come with four replacement filters and can be ordered 
from NICO Corporation by calling 317-660-7118 and asking for part number STX0350. 

Use 

only OEM STX0350 lamps and filters when performing routine maintenance.

 

8.4   LIMITED WARRANTY  
 

 Your MyriadLX™ carries a one-year warranty from the date of shipment on workmanship and all 

defects of material. Should your product prove to have such defects within one years of the 
shipment, 

NICO Corporation 

will repair or replace the product or components without charge.  

Should your illumination product(s) need servicing under this warranty, please contact 

NICO 

Corporation

 to initiate the return process.  Warranty does not cover equipment subject to misuse, 

accidental damage, normal wear and tear or if transferred to a new owner without authorization 
from 

NICO Corporation

.This warranty gives you specific legal rights and you may also have other 

rights that vary from state to state. 
 

POST WARRANTY REPAIRS

:  Please contact NICO Corporation to initiate the process.  

 
                             In the US call: 

 

 

317-660-7118 (toll free) 

                             

 
9. 

END OF PRODUCT LIFE 

 

In accordance with the European Waste from Electrical and Electronic Equipment (WEEE) 
directive, we encourage our customers to recycle this product whenever possible.  Disposal of this 
unit must be performed in accordance with the applicable local environmental regulations.  
 
In the US a list of recyclers in your area can be found at: 

http:/www.eiae.org/. 

 
Please contact customer service to issue a return authorization to return product to manufacturer 
at the end of product life. 

 

 

 

                                

 

10.    TROUBLESHOOTING 

 

Problem

 

Solution 

 
Power indicator (refer to 4.2) 
is not lit. 

 

Check that the AC power cord is properly connected.

 

Check power input switch position. 

Check the circuit breakers.   If necessary, reset. 

Power indicator is lit, but 
Xenon lamp will not ignite.  

If any inoperable fault condition is displayed on the screen, correct 
the condition shown per section 

6.2.1.

 
 
 
 
 
 

Содержание myriad-LX

Страница 1: ...ith Digital Dimming Control Operator Manual DIST NICO Corporation 250 E 96TH Street Suite 125 Indianapolis IN 46240 USA Sunoptic Technologies 6018 Bowdendale Avenue Jacksonville FL 32216 USA EC REP AJ...

Страница 2: ...OTICES 6 2 2 NORMAL OPERATING DISPLAY 6 2 2 1 LAMP HOURS DISPLAY 6 2 2 2 LIGHT BRIGHTNESS CONTROL 6 2 2 3 STANDBY 6 2 2 4 MENU 6 2 2 4 1 RESET FILTER 6 2 2 4 2 ERROR LOG 6 2 2 4 3 TOTAL UNIT HOURS 6 2...

Страница 3: ...ource utilizing state of the art illumination technology It offers a variety of features such as 5600 K color temperature provides daylight brightness for perfect color definition Quiet operation Comp...

Страница 4: ...atements of suitability for any purpose Caution All devices connecting to the Illuminator must be classified as medical equipment Additional information processing equipment connected to the Illuminat...

Страница 5: ...y with the same type and rating of lamp Read instructions before replacing lamp Caution Do not operate illuminator without lamp in place Caution For grounding reliability use only hospital grade marke...

Страница 6: ...50 60 Hz 220 240 V AC 50 Hz Power consumption 750 watt max Regulatory Approvals UL60601 EN 60601 1 EN 60601 1 2 CAN CSA C22 2 No 601 1 M90 Equipment Class BF type Conforms to CISPR 11 Class A Mode of...

Страница 7: ...Panel No Name Function 1 Lamp switch Turns the illuminator on and off illuminates blue when turned on 2 Touch screen Controls light intensity displays notices and accesses data 3 Turret Autoshutter t...

Страница 8: ...t 2 Circuit breaker Over current protection 3 AC mains power switch and input module Accepts AC Power cord and switches on AC power Green light indicates on 4 Product label Product Label containing Mo...

Страница 9: ...door Move the lamp positioning lever found to the right of the lamp clockwise from horizontal to vertical As the positioning cones disengage the lamp should drop about 3mm Move the lamp positioning le...

Страница 10: ...6 OPERATION 6 1 POWERING UP THE ILLUMINATOR To operate the illuminator First attach the fiber to the ILLUMINATOR Turn on the rear power switch Turn on the front lamp switch The lamp switch will light...

Страница 11: ...to assure full engagement to the power connectors Lower the lamp engagement lever counter clockwise from vertical to horizontal and observe that the lamp rises slightly as it is engaged into proper o...

Страница 12: ...ed more than 1000 hours Install new STX0350 lamp or one used less than 1000 hours The main screen always displays lamp hours and notices are displayed when a lamp is approaching the end of its useful...

Страница 13: ...Turn off and restart the illuminator If the fault persists the unit needs servicing 6 2 1 8 LAMP FAULT Lamp will not strike or stay lit Replace the lamp If the fault persists the unit needs servicing...

Страница 14: ...screen will display The fan will run to reduce the temperature If acceptable reductions achieved within ten seconds the lamp will turn back on to resume normal operation 6 2 1 12 COOLING SHUTDOWN If c...

Страница 15: ...screen Lamp Hours 950 Intensity Adjust 100 _ MENU STANDBY NOTE The brightness control operates a progressive electro mechanical shutter The lamp is running at full power if the power switch is on no m...

Страница 16: ...0 hours 6 2 2 5 CHANGE FILTER AND RESET Lamp Hours 950 Change Filter and Reset Intensity Adjust 100 _ MENU STANDBY The Change Filter and Reset message is displayed flashing whenever the unit runtime h...

Страница 17: ...o the left of CHANGE FILTER AND RESET After installing a new filter touch RESET FILTER to turn off the flashing signal for the next 250 hours of unit operation 6 2 2 6 2 ERROR LOG E1 _ Error Log MENU...

Страница 18: ...d PIC The minus or plus controls will cycle between them 6 2 2 6 5 LANGUAGE English MENU Language 20 _ Lamp Hours The minus or plus controls will cycle through the choices of variation languages Press...

Страница 19: ...enings 8 MAINTENANCE SERVICING AND REPAIR WARRANTY Performance of routine maintenance is essential to proper operation of the illuminator Follow the steps below for replacing filters and lamps Regular...

Страница 20: ...rip flanges of the plastic housing of the lamp pull straight out to remove the lamp Insert a new lamp pushing firmly to assure full engagement to the power connectors Lower the lamp engagement lever c...

Страница 21: ...to a new owner without authorization from NICO Corporation This warranty gives you specific legal rights and you may also have other rights that vary from state to state POST WARRANTY REPAIRS Please...

Страница 22: ...the European Community Caution Caution Federal law restricts this device to sale by or on the order of a licensed healthcare practitioner Consult Instructions for Use CE mark Not disposable in general...

Отзывы: