8.2 Lamp Replacement  

 

WARNING! 

CERAMIC lamps are at high internal pressure when cold and at operating temperature; 
therefore, CERAMIC lamps may unexpectedly rupture resulting in discharge of hot 

fragments 

of quartz and/or glass and metal. 
Only handle lamps with protective covers in place. Do not handle lamps without their 
protective covers unless government approved safety glasses, facemasks (with neck 
protector, chest protector and gauntlets) are worn. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

This illuminator is designed to use Sunoptic Technologies

®

 

p/n STX0350 lamp module 

ONLY.  Use of any other lamp may void the warranty. 

 
 

 

To replace the lamp: 

  Open the lamp compartment door. 

 

  Move the lamp positioning lever (found to the right of the lamp) clockwise, from 

horizontal to vertical, and pull the lamp cartridge out. Grasp only the horizontal top 
and bottom grip flanges of the plastic housing of the lamp, pull straight out to remove 
the lamp. 
 

  Insert a new lamp, pushing firmly to assure full engagement to the power connectors. 

Lower the lamp engagement lever counter-clockwise, from vertical to horizontal, and 
observe that the  lamp rises about 3mm as it moves to its proper operating position. 
 

  Close the lamp compartment door. 

 

  Re-connect the power cord and turn the light source on according to 6.1. to verify that 

the new lamp works and is properly installed. 

 

NOTE 

 

If the tamper seal on the illuminator is broken, the WARRANTY WILL BE 
VOIDED.  There are no other user serviceable parts in the unit. 

 

 

 

CAUTION 

Do not touch the lamp and patient simultaneously when changing the 
lamp. 

 

CAUTION 

Always disconnect power cord and turn main switch off before lamp 
replacement. 

 

CAUTION 

Take utmost care not to hit gas-seal edge of lamp; it may cause gas 
lamp failure. 

 

 

 
 
 
 
 
 
 
 

 

CAUTION 

 
 
 
 
 
 
 
 
 
 
Lamp power connection pins at the back of the lamp compartment may 
retain stored energy.  Do not contact the lamp power connectors in the back 
of the lamp compartment. 

Содержание myriad-LX

Страница 1: ...ith Digital Dimming Control Operator Manual DIST NICO Corporation 250 E 96TH Street Suite 125 Indianapolis IN 46240 USA Sunoptic Technologies 6018 Bowdendale Avenue Jacksonville FL 32216 USA EC REP AJ...

Страница 2: ...OTICES 6 2 2 NORMAL OPERATING DISPLAY 6 2 2 1 LAMP HOURS DISPLAY 6 2 2 2 LIGHT BRIGHTNESS CONTROL 6 2 2 3 STANDBY 6 2 2 4 MENU 6 2 2 4 1 RESET FILTER 6 2 2 4 2 ERROR LOG 6 2 2 4 3 TOTAL UNIT HOURS 6 2...

Страница 3: ...ource utilizing state of the art illumination technology It offers a variety of features such as 5600 K color temperature provides daylight brightness for perfect color definition Quiet operation Comp...

Страница 4: ...atements of suitability for any purpose Caution All devices connecting to the Illuminator must be classified as medical equipment Additional information processing equipment connected to the Illuminat...

Страница 5: ...y with the same type and rating of lamp Read instructions before replacing lamp Caution Do not operate illuminator without lamp in place Caution For grounding reliability use only hospital grade marke...

Страница 6: ...50 60 Hz 220 240 V AC 50 Hz Power consumption 750 watt max Regulatory Approvals UL60601 EN 60601 1 EN 60601 1 2 CAN CSA C22 2 No 601 1 M90 Equipment Class BF type Conforms to CISPR 11 Class A Mode of...

Страница 7: ...Panel No Name Function 1 Lamp switch Turns the illuminator on and off illuminates blue when turned on 2 Touch screen Controls light intensity displays notices and accesses data 3 Turret Autoshutter t...

Страница 8: ...t 2 Circuit breaker Over current protection 3 AC mains power switch and input module Accepts AC Power cord and switches on AC power Green light indicates on 4 Product label Product Label containing Mo...

Страница 9: ...door Move the lamp positioning lever found to the right of the lamp clockwise from horizontal to vertical As the positioning cones disengage the lamp should drop about 3mm Move the lamp positioning le...

Страница 10: ...6 OPERATION 6 1 POWERING UP THE ILLUMINATOR To operate the illuminator First attach the fiber to the ILLUMINATOR Turn on the rear power switch Turn on the front lamp switch The lamp switch will light...

Страница 11: ...to assure full engagement to the power connectors Lower the lamp engagement lever counter clockwise from vertical to horizontal and observe that the lamp rises slightly as it is engaged into proper o...

Страница 12: ...ed more than 1000 hours Install new STX0350 lamp or one used less than 1000 hours The main screen always displays lamp hours and notices are displayed when a lamp is approaching the end of its useful...

Страница 13: ...Turn off and restart the illuminator If the fault persists the unit needs servicing 6 2 1 8 LAMP FAULT Lamp will not strike or stay lit Replace the lamp If the fault persists the unit needs servicing...

Страница 14: ...screen will display The fan will run to reduce the temperature If acceptable reductions achieved within ten seconds the lamp will turn back on to resume normal operation 6 2 1 12 COOLING SHUTDOWN If c...

Страница 15: ...screen Lamp Hours 950 Intensity Adjust 100 _ MENU STANDBY NOTE The brightness control operates a progressive electro mechanical shutter The lamp is running at full power if the power switch is on no m...

Страница 16: ...0 hours 6 2 2 5 CHANGE FILTER AND RESET Lamp Hours 950 Change Filter and Reset Intensity Adjust 100 _ MENU STANDBY The Change Filter and Reset message is displayed flashing whenever the unit runtime h...

Страница 17: ...o the left of CHANGE FILTER AND RESET After installing a new filter touch RESET FILTER to turn off the flashing signal for the next 250 hours of unit operation 6 2 2 6 2 ERROR LOG E1 _ Error Log MENU...

Страница 18: ...d PIC The minus or plus controls will cycle between them 6 2 2 6 5 LANGUAGE English MENU Language 20 _ Lamp Hours The minus or plus controls will cycle through the choices of variation languages Press...

Страница 19: ...enings 8 MAINTENANCE SERVICING AND REPAIR WARRANTY Performance of routine maintenance is essential to proper operation of the illuminator Follow the steps below for replacing filters and lamps Regular...

Страница 20: ...rip flanges of the plastic housing of the lamp pull straight out to remove the lamp Insert a new lamp pushing firmly to assure full engagement to the power connectors Lower the lamp engagement lever c...

Страница 21: ...to a new owner without authorization from NICO Corporation This warranty gives you specific legal rights and you may also have other rights that vary from state to state POST WARRANTY REPAIRS Please...

Страница 22: ...the European Community Caution Caution Federal law restricts this device to sale by or on the order of a licensed healthcare practitioner Consult Instructions for Use CE mark Not disposable in general...

Отзывы: