3
EN
TABLE 2 - Limits in relation to the length of the gate
RUN400HS
RUN1200HS
Leave
width (m)
Max. no.
of cycles/
hour
Max. no. of
consecu-
tive cycles
Max. no.
of cycles/
hour
Max. no. of
consecu-
tive cycles
Up to 4
67
33
36
21
4 ÷ 6
45
26
26
15
6 ÷ 8
37
21
23
12
8 ÷ 10
29
18
17
10
10 ÷ 12
25
15
14
8
12 ÷ 14
22
13
13
7
TABLE 3 - Limits in relation to the weight of the gate
RUN400HS
RUN1200HS
Gate weight (kg)
% cycles
% cycles
50 ÷ 100
100%
100%
100 ÷ 200
50
80
200 ÷ 400
30
75
400 ÷ 550
---
60
550 ÷ 800
---
50
800 ÷ 1000
---
40
1000 ÷ 1200
---
30
3.2.1 - Product durability
Durability is the average economic life span of the product . The value of the life
span is strongly influenced by the intensity of the manoeuvres, i.e. the sum of all
factors that contribute to product wear, see
Table 4
.
To estimate the life span of your automated device, proceed as follows:
01.
Add the values of the items in
Table 4
regarding the system conditions;
02.
In
Graph 1
from the value obtained above, trace a vertical line until it inter-
sects the curve; from this point trace a horizontal line until it intersects the
line of the “manoeuvre cycles” . The obtained value is the estimated life
span of your product .
The lifetime values specified in the graph are only obtainable if the maintenance
schedule is strictly observed (see chapter “Maintenance schedule”) . The esti-
mation of durability is made on the basis of design calculations and the results
of tests performed on prototypes . As it is only an estimation, it does not repre-
sent any form of guarantee on the effective life span of the product .
Sample durability calculation: automation of a gate with a door 10 m long with a
weight of 150 Kg, installed near the sea:
Table 4 shows the “severity index” for this type of installation: 15% (length of gate), 30%
(weight of gate) and 10% (ambient temperature > 40°C or < 0°C or humidity > 80%”).
These indicators must be added together to obtain the overall severity index, which is
in this case 55%. With the value identified (55%), look at the horizontal axis of Graph
1 (“severity index”), and identify the value corresponding to the number of “manoeuvre
cycles” our product will be able to perform in its life span, about 180,000 cycles.
TABLE 4 - Estimated durability in relation
to the cycle severity index
Severity index %
Run
400HS
1200HS
Gate length m
Up to 6
5%
5%
6 ÷ 9
10%
10%
9 ÷ 12
15%
15%
12 ÷ 14
20%
20%
Gate weight (kg)
50 ÷ 100
10%
5%
100 ÷ 200
30%
10%
200 ÷ 400
60%
20%
400 ÷ 550
-
30%
550 ÷ 800
-
40%
800 ÷ 100
-
50%
100 ÷ 1200
-
60%
Other fatigue factors
(to be considered
if the probability of occurrence is greater
than 10%)
Surrounding temperature greater than
40°C or lower than 0°C or humidity
greater than 80%
10%
10%
Presence of dust and sand
15%
15%
Presence of salinity
20%
20%
Operation interrupted by photocell
10%
10%
Operation interrupted by Stop
20%
20%
Active peak force
10%
10%
Total severity index %:
GRAPH 1
Severity index %
Durability in cycles
0
50.000
10
%
20
%
30
%
40
%
50
%
60
%
70
%
80
%
90
%
100
%
100.000
150.000
200.000
250.000
300.000
350.000
400.000
450.000
500.000
3.3 - Works in preparation for installation
fig. 2
provides an example of an automation system, produced using
Nice
components
:
1
Key switch
2
FT210B receiver
3
Photocells
4
FT210B transmitter
5
Main mobile edge
6
Open stop bracket
7
Rack
8
Flasher with integral antenna
9
RUN
10
Closed stop bracket
11
Secondary mobile edge (optional)
12
Transmitter
These parts are positioned according to a typical standard layout . With refer-
ence to fig. 2, locate the approximate position for installation of each com
-
ponent envisaged in the system .
Important
– Before installation, prepare the
electric cables required for the system, with reference to
fig. 2
and to “
Table
5 - Technical specifications of electric cables
” .
Caution
- When laying the ducting for routing the electrical cables, also take
into account that due to possible deposits of water in the routing ducts, the
connection pipelines might create condensate in the control unit, with conse-
quent damage to the electronic circuits .
Содержание RUN1200HS
Страница 3: ...3 8 10 12 9 11 1 2mm 13 3 8 mm 14 1 2 3 4 ...
Страница 6: ...6 2 1 1 2 23 1 3 2 4 5 6 22 ...
Страница 22: ......
Страница 38: ......
Страница 54: ......
Страница 70: ......
Страница 86: ......
Страница 102: ......
Страница 130: ......
Страница 131: ......
Страница 132: ...IS0239A04MM_28 06 2016 www niceforyou com Nice SpA Oderzo TV Italia info niceforyou com ...