PROGRAMMING
7.1 - Preset functions
The RUN control unit has a number of programmable functions . These func-
tions are set to a configuration which should satisfy most automations .
7.2 - Programming keys
The RUN control unit features three keys that can be used to command the
control unit both during tests and programming .
Open
The “OPEN” key enables the user to control the openings of the
s
gate or move the programming point upwards
Stop
The “STOP” key enables the user to stop the manoeuvre, or when
Set
pressed for 5 seconds enables access to programming mode
Close
The “CLOSE” key enables the user to close the door or scroll
t
down through the programming steps
Stop Set
Close
Open
SCA
Flash
Bluebus
Stop
L1 L2 L3 L4 L5 L6 L7 L8
1.6A T
7.3 - Programming
On the RUN control unit, a number of programmable functions are available . The functions are adjusted using 3 keys on the control unit:
[
s
]
[Set]
[
t
]
and are
displayed by 8 leds:
L1….L8
.
The programmable functions available on RUN are set out on 2 levels:
Level one:
the functions can be adjusted in ON-OFF (active or inactive) modes . In this case, each of the leds
L1….L8
indicates one function; if it is lit the function
is active, if it is OFF, the function is not active; see Table 6 .
Level two:
the parameters can be adjusted on a scale of values (from 1 to 8) .In this case, each of the leds
L1….L8
indicates the set value (there are 8 possible
settings) . Please refer to Table 8 .
TABLE 6 - Programmable functions: level 1
Led
Function
Description
L1
Automatic clo-
sure
This function causes the door to close automatically after the programmed time has lapsed . The factory set Pause Time
is 30 seconds, but can be changed to 5, 15, 30, 45, 60, 80, 120 or 180 seconds . If the function is inactive, functioning
will be “semi-automatic” .
L2
Close After
Photo
This function enables the gate to be kept open for the necessary transit time only .In fact the “Photo” always causes an
automatic closure with a pause time of 5s (regardless of the programmed value) . The action changes depending on
whether the “Automatic closing” function is active or not .
When Automatic Closing is inactive: The gate always arrives to the totally open position (even if the Photo disengages
first) . On release of Photo, automatic closure is activated with a pause of 5s .
When AUTOMATIC CLOSING is active: the opening manoeuvre stops immediately after the photocells have disen-
gaged . After 5 seconds, the gate will begin to close automatically .
The “Close after photo” function is always disabled in manoeuvres interrupted by a Stop command .
If the “Close after photo” function is inactive the pause time is that which has been programmed or there is no automatic
closing if the function is inactive .
L3
Always Close
The “Always Close” function will trigger, and the gate will close if an open gate is detected when the power supply re-
turns . For safety reasons, the manoeuvre is preceded by 5s of flashing . If the function is inactive when the power supply
returns, the gate will remain still .
L4
Stand-By
This function enables the user to lower consumption to a very minimum . It is particularly useful in cases when the buffer
battery is being used . If this function is active, the control unit will switch the BLUEBUS output (and consequently the de-
vices) and all the LEDs off one minute after the end of the manoeuvre . The only LED which will remain on is the BLUEBUS
LED which will simply flash more slowly . When a command arrives, the control unit will reset to complete functioning . If
this function is inactive, there will be no reduction in the consumption .
L5
Peak
If this function is activated, the gradual acceleration at the beginning of each manoeuvre will be disconnected . It enables
the peak thrust and is useful whenever static friction is high, e .g . if snow or ice are blocking the gate . If the thrust is inac-
tive, the manoeuvre will start with a gradual acceleration .
L6
Pre-flashing
With the pre-flashing function, a 3 second pause is added between the flasher switching on and the beginning of the
manoeuvre in order to warn the user, in advance, of a potentially dangerous situation . If pre-flashing is inactive, the
flasher will switch on when the manoeuvre starts .
L7
“Close” becomes
“Open partially”
When this option is selected, all Close commands (CLOSE input or wireless control) actuate Partial Open (see led L6,
table 8) .
L8
“Slave” mode
With this option, ROBUS becomes a Slave: this allows you to synchronise two motors on opposing panels with one as
Master and one as Slave; for further information, see par . 8 .1 .5 RUN “Slave” mode .
During normal operation, leds
L1….L8
are on/off in relation to the status of the respective function; for instance,
L1
is on when “Automatic Closing” is active .
7.4 - Level one programming (ON-OFF functions)
By default, level 1 functions are all set to OFF, but can be modified at any time as described in Table 6. Take care during modification procedures, as there is a
maximum time interval of 10 seconds between pressing one key and another; otherwise the system exits the procedure automatically memorising the changes
made up to that time .
TABLE 7
Changing ON-OFF functions
01.
Press and hold the “
Set
” key for about 3 seconds;
02.
Release “
Set
”
when led
L1
starts flashing;
03.
Press “
s
” or “
t
” to move the flashing led to the function you wish to modify;
04.
Press “
Set
” to change the function's status: (short flashing = OFF; long flashing = ON);
05.
Wait 10 seconds (max .) to leave programming .
Note
– Points 3 and 4 can be repeated during the same programming phases in order to set other functions to ON or OFF.
Содержание RUN1200HS
Страница 3: ...3 8 10 12 9 11 1 2mm 13 3 8 mm 14 1 2 3 4 ...
Страница 6: ...6 2 1 1 2 23 1 3 2 4 5 6 22 ...
Страница 22: ......
Страница 38: ......
Страница 54: ......
Страница 70: ......
Страница 86: ......
Страница 102: ......
Страница 130: ......
Страница 131: ......
Страница 132: ...IS0239A04MM_28 06 2016 www niceforyou com Nice SpA Oderzo TV Italia info niceforyou com ...