GB
13
Pause Time
Step-by-step
Function
Motor speed
Open Gate
Indicator
Output
Motor force
Open
Partially
L1
L2
L3
L4
L5
L6
L1
L2
L3
L4
L5
L6
L1
L2
L3
L4
L5
L6
L1
L2
L3
L4
L5
L6
L1
L2
L3
L4
L5
L6
L1
L2
L3
L4
L5
L6
5 seconds
15 seconds
30 seconds
45 seconds
60 seconds
80 seconds
Open – stop – close - stop
Open – stop – close - close
Open – close – open - close
Condominium operation
Close
Man present
Very slow
Slow
Medium
Fast
Very fast
Extremely Fast
Open Gate Indicator Function
On if the leaf is close
On if the leaf is open
Active with 2nd radio command
Active with 3rd radio command
Active with 4th radio command
“Very light” gate
“Light” gate
“Average” gate
“Average-heavy” gate
“Heavy” gate
“Very heavy” gate
0,5 m
1 m
1,5 m
2 m
2,5 m
3 m
7.2.2) Level one programming (ON-OFF functions).
Level 1 functions are all factory set to “OFF”. However, they can be changed at any time as shown in Table 13. Follow the procedure carefully, as there
is a maximum time of 10 seconds between pressing one key and another. If a longer period of time lapses, the procedure will finish automatically and
memorize the modifications made up to that stage.
1.
Press the key
[Set]
and hold it down (approx. 3 s)
3s
2.
Release the
[Set]
key when L1 LED starts flashing
L1
3.
Press keys
[
▲
]
or
[
▼
]
to move the flashing LED onto the LED representing the function which is
to be changed.
o
4.
Press the
[Set]
key to change the state of the function (short flashing = OFF; long flashing = ON)
5.
Wait 10 seconds before leaving the programme to allow the maximum time to lapse.
10s
Note: Points 3 and 4 can be repeated during the same programming phases in order to set other functions to ON or OFF.
Table 13: changing ON-OFF functions
Example
SET
SET
SET
7.2.3 Level two functions (adjustable parameters)
Table 14: programmable function list: level two
Input LED
Parameter
LED (level)
value
Description
Adjusts the pause time, namely the time
which lapses before automatic closure.
This will only have an effect if automatic
closing is active.
Manages the sequence of controls asso-
ciated to the Step-by-Step input or to the
1st radio command (see tables 4 and 5).
Adjusts the speed of the motor during nor-
mal travel.
Adjusts the function associated with the
S.C.A. output.
Adjusts the system which controls the
motor force in order to adapt it to the wei-
ght of the gate.
Adjusts the measurement of the partial ope-
ning. Partial opening can only be controlled
using the 2nd radio control (see Tables 4
and 5)
Note: “
” represents the factory setting.
L1
L2
L3
L4
L5
L6