7.2.4) Level two programming (adjustable parameters)
The adjustable parameters are factory set as shown in the table, with:“ “ .However, they can be changed at any time, as shown in Table
15. Follow the procedure carefully as there is a maximum time of 10 seconds between pressing one key and another. If more time lapses,
the procedure will finish automatically and memorize the modifications made up to that stage.
1.
Press the key
[Set]
and hold it down (approx. 3 s)
3s
2.
Release the
[Set]
key when L1 LED starts flashing
L1
3.
Press keys
[
▲
]
or
[
▼
]
to move the flashing LED to the “input LED” which represents the parameter
which is to be modified.
o
4.
Press the key
[Set]
and hold it down during step 5 and 6
5.
Wait approx. 3 seconds, after which the LED representing the current level of the parameter which is
to be modified will light up.
6.
Press keys
[
▲
]
or
[
▼
]
to move the LED which represents the parameter value.
o
7.
Release the key
[Set]
8.
Wait 10 seconds before leaving the programme to allow the maximum time to lapse.
10s
Note: Points 3 to 7 can be repeated during the same programming phases in order to set other functions to ON or OFF.
Table 15: changing the adjustable parameters
Example
SET
SET
SET
SET
7.2.5) Level one programming example (ON-OFF functions).
The sequence to follow in order to change the factory settings of the functions for activating “Automatic Closing” (L1) and “Always Close”
(L3) have been included as examples.
1.
Press the key
[Set]
and hold it down (approx. 3 s)
3s
2.
Release the
[Set]
key when L1 LED starts flashing
L1
3.
Press the
[Set]
key once to change the state of the function associated with L1 (Automatic Closing).
LED L1 will now flash with long flashes.
L1
4.
Press the
[
▼
]
key twice to move the flashing LED to LED L3.
L3
5.
Press the
[Set]
key once to change the state of the function associated with L3 (Always Close).
LED L3 will now flash with long flashes.
6.
Wait 10 seconds before leaving the programme to allow the maximum time to lapse.
10s
Once these operations have been completed, LEDs L1 and L3 must remain on to indicate that the “Automatic Closing” and “Always
Close” functions are active.
Table 16: Level one programming example
Example
SET
SET
SET
SET
All the parameters can be adjusted as required without any con-
traindication; only the adjustment of the “motor force” could require
special care:
• Do not use high force values to compensate for points of abnormal
friction on the leaf. Excessive force can compromise the operation
of the safety system or damage the leaf.
• If the “motor force” control is used to assist the impact force reduc-
tion system, measure the force again after each adjustment in
compliance with EN standard 12445.
• Wear and weather conditions may affect the movement of the
gate, therefore periodic re-adjustments may be necessary.