6
3.2) Fixing the control unit
Insert the two screws in the upper holes provided, sliding them on the guide as in fig. 3a and partly screwing them in. Turn the control unit
through 180° and perform the same operation with the other 2 screws. Fix the control unit on to the wall.
Fix the cover on the desiderd part (with opening on the right or left), press firmly on the arrows.
To remove the cover, press with a screwdriver on the join and push upwards at the same time.
!
The installation must be carried out by qualified personnel in compliance with current legislation, standards and regulations,
and the directions provided in this manual.
3) Installation
3.1) Preliminary checks
Before proceeding with the installation:
• Check that all the materials are in excellent condition, suitable for
use and compliant with current standards.
• Ensure that the structure of the gate is suitable for automation.
• Ensure that the mounting positions of the various devices are pro-
tected from impact and that the mounting surfaces are sufficiently
sturdy.
• Install cable or pipe leads only at the bottom of the unit; for no
reason whatsoever must the side and top walls be perforated. The
cables must only enter the unit from the bottom!
• Insert suitable mechanical stops, anchored to the ground, both for
opening and closing manoeuvres.
• Components must never be immersed in water or other liquids.
Keep away from heat sources and open flames; in acid, saline
or potentially explosive atmosphere; this could damage A60 and
cause malfunctions or hazardous situations.
• If there is an access door in the leaf, or within the range of move-
ment of the gate, make sure that it does not obstruct normal travel.
Mount a suitable interlock system if necessary.
• Only connect the control unit to a power supply line equipped with
a safety grounding system.
• The power supply line must be protected by suitable magnetother-
mal and differential switches.
• A disconnection device must be inserted in the power supply
line from the electrical mains (the distance between the contacts
must be at least 3.5mm with an overvoltage category of III) or
equivalent system, for example an outlet and relative plug. If the
disconnection device for the power supply is not mounted near the
automation, it must have a locking system to prevent unintentional,
unauthorised connection.
3a
3b
3c
3d
EN
www.metalines.com
Содержание mindy A60
Страница 104: ...104 RU 3 2 3a 180 3 3 1 A60 3 5 III 3a 3b 3c 3d www metalines com sales metalines com...
Страница 106: ...106 RU 5 5a 2 EN 954 1 12 1996 10 5 5a 1 75 17 18 1 19 24 5a 10 1 1 3 5 www metalines com sales metalines com...
Страница 107: ...107 RU 3 6 17 18 24 OK NC FCA FCC M1 8 10 M2 11 13 OK 1 3 www metalines com sales metalines com...
Страница 109: ...109 RU 5 4 1 5 1 1 2 3 4 5 5 6 1 7 8 9 10 11 12 1 www metalines com sales metalines com...
Страница 111: ...111 RU 1 1 2 3 4 5 1 6 7 1 1 8 EN 12445 6 6 1 1 A60 10 2 CE 3 4 5 6 7 12 2 www metalines com sales metalines com...
Страница 113: ...113 RU Nice Nice A60 www metalines com sales metalines com...