![Nice MhouseKit SL1W Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/nice/mhousekit-sl1w/mhousekit-sl1w_instructions-and-warnings-for-installation-and-use_1686909028.webp)
26
– English
English
10.6 - DIAGNOSTICS AND SIGNALS
A few devices give out special signals that allow you to recognise the
operating status or possible malfunctions.
10.6.1 - Photocells
The photocells include LEDs that allow you to check their operational
state at any time. For led “
A
” (
fig. 45
) see
Table 14
. For led “
B
” (
fig. 45
)
see
Table 16
.
TABLE 14 (PH100W)
LED “A”
Status
Action
Off
Indication with batteries inserted: the device is
not powered or is faulty
Check that the battery is inserted and with the correct polarity;
if so, check the battery's charge; if this is lower than 1V the
battery is empty. If the battery is charged then most likely the
photocell is faulty.
1 fast red flash each second
Indication resulting from insertion of the battery
or pressing the key; the device is not paired
with any system (factory condition)
Normal operation; the photocell is ready to be learned by the
CL1W.
2 fast red f pause for
1 second
Indication resulting from the insertion of the
battery or the pressure of the key; the device
is not part of a network, and the procedure for
its installation has been activated and device
is waiting to be recognised by a control unit;
this procedure is activated when you insert
the battery in the device or by pressing the
keypad; it has a duration of 10 seconds from
battery insertion or from the last press of the
button, after which it deactivates automatically
if no control unit has recognised it
Normal operation; if you want the device in question to be
added to the system, activate the device recognition procedure
on the CL1W control unit.
2 fast green f pause
for 1 second
Indication following battery insertion when the
automation is stopped; the device is paired
with a system and is communicating correctly
with the control unit
Normal operation
1 fast green flash followed by
1 fast red flash + 1 second
pause
Indication following battery insertion when the
automation is stopped; the device is paired
with a system but the control unit does not
communicate (could be switched off)
Check that the automation is actually stopped, that there is no
testing procedure in progress, and that it is powered and not in
stand-by; if the previous tests are positive check the quality of
the radio signal received from the device
1 flash per second, green on
the transmitter
The automation is moving or in test
Normal operation; if the indicator colour is red, see the note (*)
1 slow flash per second,
green on the receiver
The automation is moving or in test and the
device is receiving an optimum infrared signal
level
Normal operation; if the indicator colour is red, see the note (*)
1 slow green flash, on receiver
(**)
The automation is moving or in test and the
device is receiving a good infrared signal level
Normal operation; if the indicator colour is red, see the note (*)
1 fast green flash, on receiver
(**)
The automation is moving or in test and the
device is receiving a poor infrared signal level
Normal operation but check the TX-RX alignment and that the
glasses are properly cleaned; if the indicator colour is red, see
note (*)
1 very quick flash, green on
the receiver
The automation is moving or in test and the
device is receiving a bad infrared signal level
If normal operation is limited, check the TX-RX alignment and
that the glasses are properly cleaned; if the indicator colour is
red, see note (*)
Green led steady on
The RX is receiving no signal
Check for any obstruction between TX and RX. Check that
the LED on TX is flashing slowly. Check the TX-RX alignment
If normal operation is limited, check the TX-RX alignment and
that the glasses are properly cleaned; if the indicator colour is
red, see note (*)
(*) Note - If the indicator colour is red, one of the following problems may be identified: 1) The maximum number of daily manoeuvres has been
exceeded for a long period. - 2) The battery is old and should be replaced. - 3) The solar cell used as a solar charger is damaged. - 4) The device
does not receive sunlight and consequently cannot charge the battery.
If the battery is fully charged the led colour is green; otherwise it is red
(**) Note - There are 10 flashing frequencies which indicate the IR signal reception power
Содержание MhouseKit SL1W
Страница 2: ......
Страница 11: ...English 9 English 5 7 8 9 10 0 50 motor mounted to the left motor mounted to the right 6 36 50 0 50 50 ...
Страница 12: ...10 English English 11 12 14 13 170 170 1 200 200 ...
Страница 13: ...English 11 English 18 19 60 17 50 0 50 0 50 50 motor mounted to the left motor mounted to the right 15 16 A ...
Страница 40: ......
Страница 49: ...Italiano 9 Italiano 5 7 8 9 10 0 50 motore fissato a sinistra motore fissato a destra 6 36 50 0 50 50 ...
Страница 50: ...10 Italiano Italiano 11 12 14 13 170 170 1 200 200 ...
Страница 51: ...Italiano 11 Italiano 18 19 60 17 50 0 50 0 50 50 motore fissato a sinistra motore fissato a destra 15 16 A ...
Страница 78: ......
Страница 87: ...Français 9 Français 5 7 8 9 10 0 50 moteur placé à gauche moteur placé à droite 6 36 50 0 50 50 ...
Страница 88: ...10 Français Français 11 12 14 13 170 170 1 200 200 ...
Страница 89: ...Français 11 Français 60 16 18 19 17 50 0 50 0 50 50 moteur placé à gauche moteur placé à droite 15 A ...
Страница 116: ......
Страница 125: ...Polski Polski 9 5 7 8 9 10 0 50 silnik przymocowany z lewej silnik przymocowany z prawej 6 36 50 0 50 50 ...
Страница 126: ...Polski 10 Polski 11 12 14 13 170 170 1 200 200 ...
Страница 127: ...Polski Polski 11 18 19 60 17 50 0 50 0 50 50 silnik przymocowany z lewej silnik przymocowany z prawej 15 16 A ...
Страница 154: ......
Страница 155: ......