ENGLISH –
15
LEVEL 2 FUNCTIONS (ADJUSTABLE PARAMETERS)
Entry
LED
Parameter
LED
(level)
Set value
Description
L2
Step-by-Step
function
L1
Open - Stop - Close - Stop
Controls the sequence of commands
associated with the “SbS”, “Open”
and “Close” inputs or the radio
control.
Note:
setting
L4
,
L5
,
L7
and
L8
, the
behaviour of the “Open” and “Close”
commands also changes.
L2
Open - Stop - Close - Open
L3
Open - Close - Open - Close
L4
CONDOMINIUM
During the opening manoeuvre
, the “Step-by-Step” and
“Open” commands do not cause any effect; instead the “Close”
command causes the movement to reverse, namely the closing
of the gate leaves.
During the closing manoeuvre
, the “Step-by-Step” and
“Open” commands cause a reversal of the movement, namely
the opening of the gate leaves; instead the “Close” command
does not cause any effect.
L5
CONDOMINIUM 2
During the opening manoeuvre
, the “Step-by-Step” and
“Open” commands do not cause any effect; instead the “Close”
command causes the movement to reverse, namely the closing
of the gate leaves. If the sent command remains for more than 2
seconds, a “Stop” command is executed.
During the closing manoeuvre
, the “Step-by-Step” and
“Open” commands cause a reversal of the movement, namely
the opening of the gate leaves; instead the “Close” command
does not cause any effect. If the sent command remains for
more than 2 seconds, a “Stop” command is executed.
L6
STEP-BY-STEP 2 (less than 2 seconds causes partial opening)
L7
HOLD-TO-RUN
The manoeuvre is only executed if the sent command remains; if
the command is interrupted, the manoeuvre stops.
L8
“Semi-automatic” opening, “hold-to-run” closing.
L3
Closing
manoeuvre
motor
slowdown
speed
L1
Level 1 - Minimum speed
Adjusts the closing manoeuvre
slowdown speed.
L2
Level 2 - ...
L3
Level 3 - ...
L4
Level 4 - ...
L5
Level 5 - ...
L6
Level 6 - ...
L7
Level 7 - ...
L8
Level 8 - Maximum speed
L4
Closing
manoeuvre
motor
slowdown
position
L1
40%
Adjusts the position where the motor
starts slowing down during the
closing manoeuvre (in percentage
with respect to the maximum
position).
L2
42%
L3
43%
L4
44%
L5
45%
L6
47%
L7
49%
L8
50%
L5
Motor force
L1
Level 1 - Minimum force
Adjusts the force of both motors.
L2
Level 2 - ...
L3
Level 3 - ...
L4
Level 4 - ...
L5
Level 5 - ...
L6
Level 6 - ...
L7
Level 7 - ...
L8
Level 8 - Maximum force
L6
Motor
discharge after
closing
L1
No discharge
Adjusts the duration of the “brief
reversal” of both motors, after
completing the closing manoeuvre,
to reduce the residual final thrust (in
ms).
L2
Level 1 - Minimum discharge (nearly 100 ms)
L3
Level 2 - ...
L4
Level 3 - ...
L5
Level 4 - ...
L6
Level 5 - ...
L7
Level 6 - ...
L8
Level 7 - Maximum discharge (800 ms)
Содержание MC824HHS