LEVEL 2 FUNCTIONS (ADJUSTABLE PARAMETERS)

Entry 

LED

Parameter

LED 

(level)

Set value

Description

L2

Step-by-Step 

function

L1

Open - Stop - Close - Stop

Controls the sequence of commands 

associated with the “SbS”, “Open” 

and “Close” inputs or the radio 

control.

Note:

setting 

L4

L5

L7

 and 

L8

, the 

behaviour of the “Open” and “Close” 

commands also changes.

L2

Open - Stop - Close - Open

L3

Open - Close - Open - Close

L4

CONDOMINIUM

During the opening manoeuvre

, the “Step-by-Step” and 

“Open” commands do not cause any effect; instead the “Close” 

command causes the movement to reverse, namely the closing 

of the gate leaves.

During the closing manoeuvre

, the “Step-by-Step” and 

“Open” commands cause a reversal of the movement, namely 

the opening of the gate leaves; instead the “Close” command 

does not cause any effect.

L5

CONDOMINIUM 2

During the opening manoeuvre

, the “Step-by-Step” and 

“Open” commands do not cause any effect; instead the “Close” 

command causes the movement to reverse, namely the closing 

of the gate leaves. If the sent command remains for more than 2 

seconds, a “Stop” command is executed.

During the closing manoeuvre

, the “Step-by-Step” and 

“Open” commands cause a reversal of the movement, namely 

the opening of the gate leaves; instead the “Close” command 

does not cause any effect. If the sent command remains for 

more than 2 seconds, a “Stop” command is executed.

L6

STEP-BY-STEP 2 (less than 2 seconds causes partial opening)

L7

HOLD-TO-RUN

The manoeuvre is only executed if the sent command remains; if 

the command is interrupted, the manoeuvre stops.

L8

“Semi-automatic” opening, “hold-to-run” closing.

L3

Closing 

manoeuvre 

motor 

slowdown 

speed

L1

Level 1 - Minimum speed

Adjusts the closing manoeuvre 

slowdown speed.

L2

Level 2 - ...

L3

Level 3 - ...

L4

Level 4 - ...

L5

Level 5 - ...

L6

Level 6 - ...

L7

Level 7 - ...

L8

Level 8 - Maximum speed

L4

Closing 

manoeuvre 

motor 

slowdown 

position

L1

40%

Adjusts the position where the motor 

starts slowing down during the 

closing manoeuvre (in percentage 

with respect to the maximum 

position).

L2

42%

L3

43%

L4

44%

L5

45%

L6

47%

L7

49%

L8

50%

L5

Motor force

L1

Level 1 - Minimum force

Adjusts the force of both motors.

L2

Level 2 - ...

L3

Level 3 - ...

L4

Level 4 - ...

L5

Level 5 - ...

L6

Level 6 - ...

L7

Level 7 - ...

L8

Level 8 - Maximum force

L6

Motor 

discharge after 

closing

L1

No discharge

Adjusts the duration of the “brief 

reversal” of both motors, after 

completing the closing manoeuvre, 

to reduce the residual final thrust (in 

ms).

L2

Level 1 - Minimum discharge (nearly 100 ms)

L3

Level 2 - ...

L4

Level 3 - ...

L5

Level 4 - ...

L6

Level 5 - ...

L7

Level 6 - ...

L8

Level 7 - Maximum discharge (800 ms)

Содержание MC824HHS

Страница 1: ...Nice MC824HHS Control unit EN Instructions and warnings for installation and use...

Страница 2: ...care by avoiding crushing impacts falls or contact with liquids of any kind Do not place the product near sources of heat nor expose it to open flames All these actions can damage the product and caus...

Страница 3: ...type radio receiver paragraph and an IBT4N type connector which through the IBT4N interface can be used to connect BusT4 devices such as the Oview programmer see the Connecting the IBT4N interface pa...

Страница 4: ...ENTIFICATION AND OVERALL DIMENSIONS The overall dimensions and label A that allow for identifying the product are shown in Figure 2 232 mm 310 mm 122 mm A 2 3 4 TYPICAL INSTALLATION Figure 3 shows an...

Страница 5: ...ectronic circuits 3 5 INSTALLING THE CONTROL UNIT a Secure the control unit to an unmovable vertical flat surface adequately protected against possible impacts The lower part of the control unit must...

Страница 6: ...ositioned in sight of the automation If located in a concealed position it must be equipped with a system that prevents inadvertent or unauthorised reconnection of power to avoid potential hazards 4 2...

Страница 7: ...open contacts NC normally closed contacts or devices with 8 2 k fixed resistor output such as sensitive edges can be connected to this input Each device connected to this input will be individually r...

Страница 8: ...FOTO PHOTO External photocell h 50 activated during the closing phase stops and reverses the gate s movement FOTO II PHOTO II External photocell h 100 activated during the closing phase stops and reve...

Страница 9: ...mode to be assigned to the motor see Table 4 Close Open SbS Stop Bluebus 1 2 3 4 5 6 7 8 9 10 11 12 A 13 m The motor selector must be set before activating the mechanical stop learning function m Any...

Страница 10: ...trolled by M2 press f or h to stop the learning phase At this point reverse the connections of motors M1 and M2 on the terminals on the control unit and those of the respective encoders Then repeat th...

Страница 11: ...button is released LED L7 will start flashing 9 LED L7 flashes position 1 of M1 to command and move motor 1 to position 1 Figure 14 press and hold the f or h button Once the position is reached relea...

Страница 12: ...ether the leaves can be opened and closed with a force below 390 N 3 lock the motors as described in the respective instruction manual 4 using the control devices transmitter control button key select...

Страница 13: ...ction short flash OFF long flash ON 5 wait 10 seconds maximum time to exit the programming mode l To set other functions to ON or OFF while the procedure is running repeat points 2 and 3 during the ph...

Страница 14: ...10 seconds to press the buttons consecutively during the programming procedure after which time the procedure terminates automatically and memorises the changes made up to then To perform Level 2 pro...

Страница 15: ...of the movement namely the opening of the gate leaves instead the Close command does not cause any effect If the sent command remains for more than 2 seconds a Stop command is executed L6 STEP BY STEP...

Страница 16: ...nsmitter or key selector etc If everything functions properly the gate will move normally otherwise proceed with point 2 2 within 3 seconds press the control again and hold it down 3 after roughly 2 s...

Страница 17: ...e cause and increase the motor force if necessary 4 short red flashes 1 second pause 4 short red flashes Intervention of the STOP input At the start of the manoeuvre or during the movement itself the...

Страница 18: ...blown verify the cause and replace it with one having the same characteristics Green LED always on Serious anomaly There is a serious problem try disconnecting the power supply to the control unit an...

Страница 19: ...ton to shift flashing of the LED to L8 Anomaly list parameter 4 keep the g button pressed down it must be kept pressed throughout phases 5 and 6 5 wait roughly 3 seconds after which LED L1 correspondi...

Страница 20: ...mation Unlock or only from Oview the following commands Unlock and close and Unlock and open 12 Lock automation Triggers the stoppage of the manoeuvre and locks the automation the control unit will no...

Страница 21: ...CT MAINTENANCE Being an electronic part the control unit does not require any special maintenance Nonetheless the system should be regularly checked to ensure that it works efficiently at least every...

Страница 22: ...command SbS input for normally open contacts the closing of the contact triggers the Step by Step command OPEN input for normally open contacts the closing of the contact triggers the OPEN command CLO...

Страница 23: ...according to the requirements envisaged for partly completed machinery Annex II part 1 section B Directive 2006 42 EC of the EUROPEAN PARLIAMENT AND COUNCIL of 17 May 2006 related to machinery and am...

Страница 24: ...24 ENGLISH NOTES...

Страница 25: ...ystem or the programming and adjustment parameters of the control unit your installer is exclusively responsible for these operations Failure or power outage while waiting for your installer to interv...

Страница 26: ...26 ENGLISH NOTES...

Страница 27: ...ENGLISH 27 NOTES...

Страница 28: ...www niceforyou com Nice SpA Via Callalta 1 31046 Oderzo TV Italy info niceforyou com IDV0779A00EN_27 11 2020...

Отзывы: