background image

14 

– ENGLISH

LEVEL 1 FUNCTIONS (ON-OFF)

LED

Function

Description

L5

Electric lock / 

Courtesy light

Function ENABLED:

 the “electric lock” output switches its operation to “courtesy light”.

Function NOT ENABLED:

 the output functions as an electric lock.

L6

Pre-flashing

Function ENABLED:

 the warning light starts flashing 3 seconds before the start of the manoeuvre to signal in 

advance a dangerous situation.

Function NOT ENABLED:

 the warning light starts flashing when the manoeuvre starts.

L7

“Close” becomes 

“Partial Open 1”

Function ENABLED:

 the “Close” input of the control unit switches its operation to “Partial Open 1”.

L8

“Gate open 

indicator” or 

“Maintenance 

indicator”

Function ENABLED:

 the “gate open indicator” output of the control unit switches its operation to 

“maintenance indicator”.

Function NOT ENABLED:

 the output functions as a “gate open indicator”.

6.3  LEVEL 2 PROGRAMMING (ADJUSTABLE PARAMETERS)

All the Level 2 parameters are factory-set as highlighted in “

GREY

” in “

Table 7

” and can be modified at any time. The parameters can 

be set to a scale of 1 to 8. The check the value corresponding to each LED, refer to “

Table 7

”.

6.3.1 Level 2 programming procedure

The user has maximum 10 seconds to press the buttons consecutively during the programming procedure, 

after which time the procedure terminates automatically and memorises the changes made up to then.

To perform Level 2 programming:

1. 

press and hold the 

g

 button until LED “

L1

” starts flashing

2. 

release the 

g

 button when LED “

L1

” starts flashing

3. 

press the 

f

 or 

h

 button to move the flashing LED to the “

entry LED

” associated with the parameter to be 

modified

4. 

press and hold the 

g

 button. With the 

g

 button pressed:

 

wait roughly 3 seconds, until the LED representing the current level of the parameter to be modified lights up

 

press the 

f

 or 

h

 button to shift the LED associated with the parameter’s value

5. 

release the 

g

 button

6. 

wait 10 seconds (maximum time) to exit the programming mode.

To set multiple parameters during the procedure's execution, repeat the operations from point 2 to point 4 

during the phase itself.

The set value highlighted in grey (“

Table 7

”) indicates that this value is the factory setting.

Table 7

LEVEL 2 FUNCTIONS (ADJUSTABLE PARAMETERS)

Entry 

LED

Parameter

LED 

(level)

Set value

Description

L1

Pause Time

L1

5 seconds

Adjusts the pause time, in other 

words, the time that elapses before 

automatic re-closure. It is only 

effective if the Close function is 

enabled.

L2

15 seconds

L3

30 seconds

L4

45 seconds

L5

60 seconds

L6

80 seconds

L7

120 seconds

L8

180 seconds

Содержание MC824HHS

Страница 1: ...Nice MC824HHS Control unit EN Instructions and warnings for installation and use...

Страница 2: ...care by avoiding crushing impacts falls or contact with liquids of any kind Do not place the product near sources of heat nor expose it to open flames All these actions can damage the product and caus...

Страница 3: ...type radio receiver paragraph and an IBT4N type connector which through the IBT4N interface can be used to connect BusT4 devices such as the Oview programmer see the Connecting the IBT4N interface pa...

Страница 4: ...ENTIFICATION AND OVERALL DIMENSIONS The overall dimensions and label A that allow for identifying the product are shown in Figure 2 232 mm 310 mm 122 mm A 2 3 4 TYPICAL INSTALLATION Figure 3 shows an...

Страница 5: ...ectronic circuits 3 5 INSTALLING THE CONTROL UNIT a Secure the control unit to an unmovable vertical flat surface adequately protected against possible impacts The lower part of the control unit must...

Страница 6: ...ositioned in sight of the automation If located in a concealed position it must be equipped with a system that prevents inadvertent or unauthorised reconnection of power to avoid potential hazards 4 2...

Страница 7: ...open contacts NC normally closed contacts or devices with 8 2 k fixed resistor output such as sensitive edges can be connected to this input Each device connected to this input will be individually r...

Страница 8: ...FOTO PHOTO External photocell h 50 activated during the closing phase stops and reverses the gate s movement FOTO II PHOTO II External photocell h 100 activated during the closing phase stops and reve...

Страница 9: ...mode to be assigned to the motor see Table 4 Close Open SbS Stop Bluebus 1 2 3 4 5 6 7 8 9 10 11 12 A 13 m The motor selector must be set before activating the mechanical stop learning function m Any...

Страница 10: ...trolled by M2 press f or h to stop the learning phase At this point reverse the connections of motors M1 and M2 on the terminals on the control unit and those of the respective encoders Then repeat th...

Страница 11: ...button is released LED L7 will start flashing 9 LED L7 flashes position 1 of M1 to command and move motor 1 to position 1 Figure 14 press and hold the f or h button Once the position is reached relea...

Страница 12: ...ether the leaves can be opened and closed with a force below 390 N 3 lock the motors as described in the respective instruction manual 4 using the control devices transmitter control button key select...

Страница 13: ...ction short flash OFF long flash ON 5 wait 10 seconds maximum time to exit the programming mode l To set other functions to ON or OFF while the procedure is running repeat points 2 and 3 during the ph...

Страница 14: ...10 seconds to press the buttons consecutively during the programming procedure after which time the procedure terminates automatically and memorises the changes made up to then To perform Level 2 pro...

Страница 15: ...of the movement namely the opening of the gate leaves instead the Close command does not cause any effect If the sent command remains for more than 2 seconds a Stop command is executed L6 STEP BY STEP...

Страница 16: ...nsmitter or key selector etc If everything functions properly the gate will move normally otherwise proceed with point 2 2 within 3 seconds press the control again and hold it down 3 after roughly 2 s...

Страница 17: ...e cause and increase the motor force if necessary 4 short red flashes 1 second pause 4 short red flashes Intervention of the STOP input At the start of the manoeuvre or during the movement itself the...

Страница 18: ...blown verify the cause and replace it with one having the same characteristics Green LED always on Serious anomaly There is a serious problem try disconnecting the power supply to the control unit an...

Страница 19: ...ton to shift flashing of the LED to L8 Anomaly list parameter 4 keep the g button pressed down it must be kept pressed throughout phases 5 and 6 5 wait roughly 3 seconds after which LED L1 correspondi...

Страница 20: ...mation Unlock or only from Oview the following commands Unlock and close and Unlock and open 12 Lock automation Triggers the stoppage of the manoeuvre and locks the automation the control unit will no...

Страница 21: ...CT MAINTENANCE Being an electronic part the control unit does not require any special maintenance Nonetheless the system should be regularly checked to ensure that it works efficiently at least every...

Страница 22: ...command SbS input for normally open contacts the closing of the contact triggers the Step by Step command OPEN input for normally open contacts the closing of the contact triggers the OPEN command CLO...

Страница 23: ...according to the requirements envisaged for partly completed machinery Annex II part 1 section B Directive 2006 42 EC of the EUROPEAN PARLIAMENT AND COUNCIL of 17 May 2006 related to machinery and am...

Страница 24: ...24 ENGLISH NOTES...

Страница 25: ...ystem or the programming and adjustment parameters of the control unit your installer is exclusively responsible for these operations Failure or power outage while waiting for your installer to interv...

Страница 26: ...26 ENGLISH NOTES...

Страница 27: ...ENGLISH 27 NOTES...

Страница 28: ...www niceforyou com Nice SpA Via Callalta 1 31046 Oderzo TV Italy info niceforyou com IDV0779A00EN_27 11 2020...