background image

Step-by-step Master

When this command is sent to the master control unit, the Mas-
ter/Slave  barriers  open  or  close,  depending  on  the  previous 
command. Input configured as normally open.

Open master

When this command is sent to the master control unit, the Mas-
ter/Slave barriers open. Input configured as normally open.

Close master

When this command is sent to the master control unit, the Mas-
ter/Slave barriers close. Input configured as normally open.

Step-by-step slave

When this command is sent to the master control unit, the Slave 
barrier opens or closes, depending on the previous command. 
Input configured as normally open.

Open slave

When this command is sent to the master control unit, the Slave 
barrier opens. Input configured as normally open.

Close slave

When this command is sent to the master control unit, the Slave 
barrier closes. Input configured as normally open.

Loop Detector (0xfd)

This parameter sets the operation of the loop detectors. The parameters of Loop1 and Loop2 can be programmed independently, except for Power and 
Calibration. The top right of the Oview screen shows the number of the loop being programmed. To change loop, use the < and > keys.
You can program the following parameters:

• Loop power (0xe6)

This is an ON / OFF parameter (the factory setting is “OFF”) used to activate/deactivate the loop detector circuits

• Loop calibration (0xe5)

This parameter is ON/OFF; the factory setting is “OFF”. When set to “ON”, a calibration procedure starts (i.e. recognition of the connected loop). 

Note

: the 

calibration automatically activates the parameter “Loop power”

• Loop sensitivity (0xe4)

Takes values from 10 to 100. The factory setting is 80. This parameters sets the minimum frequency variation of the metal body required to start a manoeuvre. 

Note

:

- set a high sensitivity to detect small metal bodies
- set a low sensitivity to detect large metal bodies

• Loop activation (0xe7)

This parameter type is ON / OFF; the factory setting is “ON”. Activating the loop means that the barrier will react as programmed when it is tripped. If the 
function is DEACTIVATED, the status of the loop is available, if one of the outputs is programmed as a loop (1, 2 or 3), with the Oview programmer.

• Loop mode (0xea)

This parameter assigns the operation following activation of the loop. If “Activate loop” is enabled and the loop command is ACTIVE, the barrier will respond 
as programmed with the Loop mode:
- open only (apartment block open)
- close only
- stop
- photo close (PHOTO with full inversion)

• Loop recalibration time (0xe9)

This can be set from 2 to 20 minutes, the factory setting is 20 minutes (=∞) and represents the maximum time for which the loop is occupied. Once this time 
has elapsed, a recalibration is automatically started to indicate that the loop is unoccupied. The 20 minute setting (=∞) ignores the time parameter and does 
not run a recalibration due to the loop being occupied.

• Loop activation mode (0xe8)

This parameter can be set from 1 to 5 (see table below). The factory setting is 
1 and represents activation of the command as a function of the behaviour of 
the loop itself. The relay = loop command signal. 

Loop

Loop

Loop

Loop

Loop

Relay

Relay

Relay

Relay

Relay

• Loop activation time (0xeb)

Can be set from 0 to 25 seconds. The factory setting is 2. This is the time “t” used by the operating modes described in the Loop activation modes table.

• Loop frequency (0xed)

Indicates the frequency of oscillation of the loop in question, in Hz. It can vary from 0 to 127000Hz. A value lower than 100000Hz  indicates that the loop is 
not connected; the control unit disables it. The best setting is in the range 30000 to 90000 Hz.

Содержание LBar

Страница 1: ...Programmable functions using the Oview programmer MBar LBar STF XBA3 Rev00 Firmware XB02a XU01 XF01 ...

Страница 2: ... a programming session followed by the log out procedure on completion of the programming procedure Note the log out procedure enables the user to prevent access by unauthorised personnel by re activating the existing password Caution In programming the password on multiple devices for example on the Oview control unit receiver etc it is advisable to use the same password for all devices including...

Страница 3: ... at the end of the wait time programmed in the function pause time If the function is not active OFF the Control unit operation mode is semiautomatic Pause time 0x81 This parameter is expressed in seconds and can be set with a value from 0 to 250 sec the factory setting is 20 sec This function enables programming on the Control unit of the required wait time which must pass between the end of an O...

Страница 4: ...n of barrier The function enables control of the force absorbed by the motor during a Closing manoeuvre Important Setting this value too high can damage the gearmotor and overheat the control unit closing deceleration force 0x4d This parameter can be set with a value from 10 to 100 the factory setting depends on the version of barrier The function enables control of the maximum force absorbed by t...

Страница 5: ...n be set with a value from 0 to 10 sec the factory setting is 3 sec This function programs the flashing time which indicates the imminent start of a Closing manoeuvre it is associated with the pre flashing function Stand by 0x8b active 0x8c This parameter is ON OFF the factory setting is OFF When this function is set to ON automation power consumption can be reduced mode 0x8e The function has 3 op...

Страница 6: ...ration opening mode This command is factory assigned to Input 2 in mode open When this command is sent the control unit activates the ap plication to complete the Opening manoeuvre until the position is reached as set in the function opening Control unit func tions installation positions opening Input configured as normally open Close Closure Program the desired mode from those listed in table 1 B...

Страница 7: ...de apartment block 1 open When this command is sent the control unit activates the ap plication to perform the opening manoeuvre only until the limit switch is reached Note This command is useful when using control photocells or a magnetic detector loop Input configured as normally open Photo Safety function Photo Program the desired mode from those listed in Table 1 F command configuration photo ...

Страница 8: ...iation of the metal body required to start a manoeuvre Note set a high sensitivity to detect small metal bodies set a low sensitivity to detect large metal bodies Loop activation 0xe7 This parameter type is ON OFF the factory setting is ON Activating the loop means that the barrier will react as programmed when it is tripped If the function is DEACTIVATED the status of the loop is available if one...

Страница 9: ...er command is sent after this one the application executes the Closing manoeuvre with the same sequence Apartment block 2 step by step This executes the sequence close stop partial open 1 partial open 1 until the position is reached as pro grammed in the function Partial Open 1 Note If another command is sent after this one the application executes the Closing manoeuvre with the same sequence Impo...

Страница 10: ...lication to perform a brief inversion in the opposite direction Closing Caution During execution of the Opening manoeuvre this command is ignored Stop When the control unit receives the command it stops the Opening manoeuvre in progress Caution During execu tion of the Opening manoeuvre this command is ignored temporary stop When the control unit receives the command it stops the Closing manoeuvre...

Страница 11: ...er TABLE 2 OUTPUT CONFIGURATION FUNCTION DESCRIPTION sca 0x01 The programmed light indicates the operating status of the control unit light off application in maximum Closing position slow flashing application Opening manoeuvre execution phase quick flashing application Closing manoeuvre execution phase light permanently on application in maximum Opening position SCA1 0x14 The programmed light ind...

Страница 12: ...nnel is not free on the control unit s receiver due to having been previously memorised with a command when the chan nel is activated by the transmitter the control unit only activates the programmed output and ignores the motor command Radio channel 4 0x12 When a transmitter sends a command this output is activated This mode is useful if installing external devices for example an auxiliary light ...

Страница 13: ...tem to be controlled with a single transmitter CAUTION If this channel is not free on the control unit s receiver due to having been previously memorised with a command when the channel is activated by the transmitter the control unit only activates the programmed output and ignores the motor command Output active 24 V DC max 10 W radio channel no 2 If this radio channel is set for the configurati...

Страница 14: ... to occupation by a metal body Loop2 Indicates when the loop is activated due to occupation by a metal body BOARD KEYS no 1 Indicates when key 1 is pressed OPEN on the control unit no 2 Indicates when key 2 is pressed STOP on the control unit no 3 Indicates when key 3 is pressed CLOSE on the control unit DIRECTION SELECTION Indicates the status of the direction selector for a manoeuvre INPUT STATU...

Страница 15: ...ata is useful to understand whether the encoder is in an overtravel position i e outside the operating zone of the absolute encoder bluebus device diagnostics This function displays the type operating status and configuration of devices connected ot the Bluebus output These parameters are described in Table 6 TABLE 6 DIAGNOSTICS of bluebus devices PARAMETER DESCRIPTION Bluebus PHOTOCELLS PHOTO Ind...

Страница 16: ...s required after performing mainte nance on the automation ADVANCED FUNCTIONS event log This function enables the display of the events generated or received by the control unit An event is a condition which changes the operating status of the control unit such as activation of an input end of a manoeuvre photocell or stop input tripped etc This section displays the date and type of an event firmw...

Отзывы: