background image

Advanced parameters

This item covers the commands available and associable with 

inputs 1 - 2 – 3

 

and the Loop Detector

 on the control unit of an automation. The commands 

available for the inputs are given in 

Table 1

; the command categories and modes are given in 

Table 1a

1b

1c etc.

Important – For correct operation 

of the control unit, the command programmed on an input must be associated with the corresponding command category and lastly the 

required operating mode.

For configure an input, proceed as follows:

01.

 In the section “Advanced parameters” select the item “input configuration” and then the input to be programmed. Select the command and confirm with 

“OK”.

02.

 Then, still in “Advanced parameters”, select “command configuration” and select the category of the command selected in step 01. Finally, select the 

operating mode. There are three available inputs:

• Input 1 

(the common of this input is 24V)

This programs Input 1, by assigning a command from among those listed in Table 1. Input 1 is factory set to “step-by-step”, “step-by-step” category and 
“open-stop-close-open” mode.

• Input 2 

(the common of this input is 12V)

This programs Input 2, by assigning a command from among those listed in Table 1. Input 2 is factory set to “open”, “opening” category and “open-stop-
open” mode.

• Input 3 

(the common of this input is 12V)

This programs Input 1, by assigning a command from among those listed in Table 1. Input 3 is factory set to “close”, “closing” category and “close-stop-
close” mode.

TABLE 1: INPUT CONFIGURATION

COMMAND

COMMAND CATEGORY

DESCRIPTION

No command

Does not perform any command.

Step-by-step

Step-by-step  Program  the  desired  mode  from 
those  given  in  Table  1-A  (“Command  configura-
tion” > “step-by-step” > operating mode ...)

The command is factory assigned to Input 1, mode “step-by-
step” and sequence “open - stop - close - open”.
When the command is sent, the control unit makes the auto-
mation run the manoeuvre following that previously (or still) in 
execution, according to the order of manoeuvres given in the 
programmed sequence. Input configured as normally open.

Partial open 1

Partial  open  Program  the  desired  mode  from 
those  listed  in  Table  1-B  (“Command  configura-
tion” > “partial open” > mode ...)

When this command is sent the control unit activates the appli-
cation to complete the Opening manoeuvre until the position is 
reached as set in the function “partial open 1”(Control unit func-
tions > installation > positions > partial open 1). Input configured 
as normally open.

Open

Opening  Program  the  desired  mode  form  those 
listed  in  Table  1-C  (“Command  configuration”  > 
“opening” > mode ...)

This command is factory assigned to Input 2, in mode “open”. 
When this command is sent the control unit activates the ap-
plication to complete the Opening manoeuvre until the position 
is reached as set in the function “opening” (Control unit func-
tions > installation > positions > opening). Input configured as 
normally open.

Close

Closure  Program  the  desired  mode  from  those 
listed  in  table  1-B  (“command  configuration”  > 
“closure” > mode ...)

This command is factory set to Input 3, with operating mode 
“close”. When this command is sent the control unit activates 
the application to complete the Closing manoeuvre until the po-
sition  is  reached  as  set  in  the  function  “closing”  (Control  unit 
functions > installation > positions > closing). Input configured 
as normally open.

Stop

Stop Program the desired mode from those listed 
in Table 1-E (“command configuration” > “stop” > 
mode ...)

When this command is sent, the control unit stops the manoeu-
vre in progress gradually and in a short time (not instantly). Input 
configured as normally open.

High priority step-by-step 

Step-by-step  Program  the  desired  mode  from 
those  given  in  Table  1-A  (“Command  configura-
tion” > “step-by-step” > operating mode ...)

When this command is sent, the control unit activates the ap-
plication to complete the next manoeuvre following the previous 
one (or still in progress) according to the sequence of manoeu-
vres as envisaged in the programmed sequence. Important – 
This command is performed even if the control unit is set with 
the  command  “block”  (see  Table  1).  Input  configured  as  nor-
mally open.

Open and block

Opening  Program  the  desired  mode  form  those 
listed  in  Table  1-C  (“Command  configuration”  > 
“opening” > mode ...)

When this command is sent the control unit activates the ap-
plication to complete the Opening manoeuvre until the position 
is reached as set in the function “opening” (Control unit func-
tions > installation > positions > opening). Input configured as 
normally open.

Close and block

Closure 

Program  the  desired  mode  from  those 

listed  in  Table  1-D  (“command  configuration”  > 
“closure” > mode ...)

When this command is sent the control unit activates the ap-
plication to complete the Closing manoeuvre until the position 
is reached as set in the function “closing”(Control unit functions 
> installation > positions > closing) and the automation is then 
blocked. Input configured as normally open.

Block

When  this  command  is  sent,  the  control  unit  is  blocked  and 
does not perform any type of command, with the exception of 
“High  priority  step-step”,  “Release”,  “Release  and  close”  and 
“Release and open”. Input configured as normally open.

Release

When this command is sent, the control unit is released restor-
ing  normal  operating  status  (all  commands  sent  can  be  per-
formed). Input configured as normally open.

Содержание LBar

Страница 1: ...Programmable functions using the Oview programmer MBar LBar STF XBA3 Rev00 Firmware XB02a XU01 XF01 ...

Страница 2: ... a programming session followed by the log out procedure on completion of the programming procedure Note the log out procedure enables the user to prevent access by unauthorised personnel by re activating the existing password Caution In programming the password on multiple devices for example on the Oview control unit receiver etc it is advisable to use the same password for all devices including...

Страница 3: ... at the end of the wait time programmed in the function pause time If the function is not active OFF the Control unit operation mode is semiautomatic Pause time 0x81 This parameter is expressed in seconds and can be set with a value from 0 to 250 sec the factory setting is 20 sec This function enables programming on the Control unit of the required wait time which must pass between the end of an O...

Страница 4: ...n of barrier The function enables control of the force absorbed by the motor during a Closing manoeuvre Important Setting this value too high can damage the gearmotor and overheat the control unit closing deceleration force 0x4d This parameter can be set with a value from 10 to 100 the factory setting depends on the version of barrier The function enables control of the maximum force absorbed by t...

Страница 5: ...n be set with a value from 0 to 10 sec the factory setting is 3 sec This function programs the flashing time which indicates the imminent start of a Closing manoeuvre it is associated with the pre flashing function Stand by 0x8b active 0x8c This parameter is ON OFF the factory setting is OFF When this function is set to ON automation power consumption can be reduced mode 0x8e The function has 3 op...

Страница 6: ...ration opening mode This command is factory assigned to Input 2 in mode open When this command is sent the control unit activates the ap plication to complete the Opening manoeuvre until the position is reached as set in the function opening Control unit func tions installation positions opening Input configured as normally open Close Closure Program the desired mode from those listed in table 1 B...

Страница 7: ...de apartment block 1 open When this command is sent the control unit activates the ap plication to perform the opening manoeuvre only until the limit switch is reached Note This command is useful when using control photocells or a magnetic detector loop Input configured as normally open Photo Safety function Photo Program the desired mode from those listed in Table 1 F command configuration photo ...

Страница 8: ...iation of the metal body required to start a manoeuvre Note set a high sensitivity to detect small metal bodies set a low sensitivity to detect large metal bodies Loop activation 0xe7 This parameter type is ON OFF the factory setting is ON Activating the loop means that the barrier will react as programmed when it is tripped If the function is DEACTIVATED the status of the loop is available if one...

Страница 9: ...er command is sent after this one the application executes the Closing manoeuvre with the same sequence Apartment block 2 step by step This executes the sequence close stop partial open 1 partial open 1 until the position is reached as pro grammed in the function Partial Open 1 Note If another command is sent after this one the application executes the Closing manoeuvre with the same sequence Impo...

Страница 10: ...lication to perform a brief inversion in the opposite direction Closing Caution During execution of the Opening manoeuvre this command is ignored Stop When the control unit receives the command it stops the Opening manoeuvre in progress Caution During execu tion of the Opening manoeuvre this command is ignored temporary stop When the control unit receives the command it stops the Closing manoeuvre...

Страница 11: ...er TABLE 2 OUTPUT CONFIGURATION FUNCTION DESCRIPTION sca 0x01 The programmed light indicates the operating status of the control unit light off application in maximum Closing position slow flashing application Opening manoeuvre execution phase quick flashing application Closing manoeuvre execution phase light permanently on application in maximum Opening position SCA1 0x14 The programmed light ind...

Страница 12: ...nnel is not free on the control unit s receiver due to having been previously memorised with a command when the chan nel is activated by the transmitter the control unit only activates the programmed output and ignores the motor command Radio channel 4 0x12 When a transmitter sends a command this output is activated This mode is useful if installing external devices for example an auxiliary light ...

Страница 13: ...tem to be controlled with a single transmitter CAUTION If this channel is not free on the control unit s receiver due to having been previously memorised with a command when the channel is activated by the transmitter the control unit only activates the programmed output and ignores the motor command Output active 24 V DC max 10 W radio channel no 2 If this radio channel is set for the configurati...

Страница 14: ... to occupation by a metal body Loop2 Indicates when the loop is activated due to occupation by a metal body BOARD KEYS no 1 Indicates when key 1 is pressed OPEN on the control unit no 2 Indicates when key 2 is pressed STOP on the control unit no 3 Indicates when key 3 is pressed CLOSE on the control unit DIRECTION SELECTION Indicates the status of the direction selector for a manoeuvre INPUT STATU...

Страница 15: ...ata is useful to understand whether the encoder is in an overtravel position i e outside the operating zone of the absolute encoder bluebus device diagnostics This function displays the type operating status and configuration of devices connected ot the Bluebus output These parameters are described in Table 6 TABLE 6 DIAGNOSTICS of bluebus devices PARAMETER DESCRIPTION Bluebus PHOTOCELLS PHOTO Ind...

Страница 16: ...s required after performing mainte nance on the automation ADVANCED FUNCTIONS event log This function enables the display of the events generated or received by the control unit An event is a condition which changes the operating status of the control unit such as activation of an input end of a manoeuvre photocell or stop input tripped etc This section displays the date and type of an event firmw...

Отзывы: