background image

Timed Courtesy light

This command enables activation of the courtesy light on the 
control unit and that programmable on Output 1. The courtesy 
light remains active for the time as programmed in the func-
tion  “courtesy  light  time”  (Control  unit  functions  >  advanced 
parameters  >  output  configuration  >  courtesy  light  time).  For 
the courtesy light connected to Output 1, the command is only 
enabled  when  this  output  is  programmed  in  “courtesy  light” 
mode (Control unit functions > advanced parameters > output 
configuration > output 1 (flash) > courtesy light). Note – When 
the courtesy light is already active and the “courtesy light timer” 
is sent again, the time set in “courtesy light time” is reset. Input 
configured as normally open.

Courtesy light: on/off

This command enables activation and deactivation of the cour-
tesy light on the control unit and that programmable on Output 
1. For the courtesy light connected to Output 1, the command 
is only enabled when this output is programmed in “courtesy 
light”  mode  (Control  unit  functions  >  advanced  parameters  > 
output configuration > output 1 (flash) > courtesy light). CAU-
TION!  –  The  courtesy  light  is  switched  off  automatically  if  the 
relative time interval elapses, as programmed in the function 
“courtesy light time” (Control unit functions > advanced param-
eters > output configuration > courtesy light time). Input config-
ured as normally open.

Apartment block

Step-by-step 

Program  the  required  operating 

mode,  ss  apartment  block  1  (“command  con-
figuration” > “step-by-step” > operating mode: ss 
apartment block 1)

This command is factory set to Input 1, with operating mode 
“ss  apartment  block  1”  and  operating  sequence  “open-  stop 
- close - open”. When the command is sent, the control unit 
makes the automation run the manoeuvre following that previ-
ously (or still) in execution, according to the order of manoeu-
vres given in the programmed sequence. Note – This apartment 
block step-by-step command is used for apartment blocks and 
in general envisages programming of all apartment block trans-
mitters with a single “apartment block step-by-step” key. Input 
configured as normally open.

Stop

Stop in open/close 

Program  the  desired  mode 

from those listed in Table 1-L (“command configu-
ration” > “Stop in open/close” > mode ...)

When this command is sent, the control unit stops the manoeu-
vre in progress and activates the application to execute the set 
operating mode. Input configured as normally closed.

Apartment block open

Opening 

Program the required operating mode, 

apartment  block  1  open  (“command  configura-
tion”  >  “opening”  >  operating  mode  apartment 
block 1 open)

When this command is sent, the control unit activates the ap-
plication to perform the opening manoeuvre only until the limit 
switch is reached. Note – This command is useful when using 
control photocells or a magnetic detector loop. Input configured 
as normally open.

Photo

Safety function

Photo 

Program  the  desired  mode  from  those 

listed  in  Table  1-F  (“command  configuration”  > 
“photo” > mode ...)

When this command is sent, the control unit activates the ap-
plication according to the selected manoeuvre type. Input con-
figured as normally closed.

Photo 2

Safety function

Photo 2 

Program  the  desired  mode  from  those 

listed  in  table  1-H  (“command  configuration”  > 
“photo 2” > mode ...)

When this command is sent, the control unit activates the ap-
plication according to the selected manoeuvre type. Input con-
figured as normally closed.

Photo 3

Safety function

Photo 3 

Program  the  desired  mode  from  those 

listed  in  table  1-I  (“command  configuration”  > 
“photo 3” > mode ...)

When this command is sent, the control unit activates the ap-
plication according to the selected manoeuvre type. Input con-
figured as normally closed.

Release and open

When  this  command  is  sent,  the  control  unit  is  released  (re-
storing normal operating status) and activates the application to 
execute an Opening manoeuvre. Input configured as normally 
open.

Release and close

When this command is sent, the control unit is released (restor-
ing normal operating status) and activates the application to ex-
ecute a Closing manoeuvre. Input configured as normally open.

Automatic opening active

This command enables the activation or deactivation of the 
function for bluebus control photocells and inputs configured in 
“apartment block open” mode. Note – the factory setting of this 
function is “active”. For example, if this function is active, when 
the control photocells are engaged, the control unit activates 
the application to execute an Opening manoeuvre. Input con-
figured as normally open.

Deactivate automatic opening

This  command  enables  deactivation  of  the  “automatic  open-
ing active” mode described above. Input configured as normally 
open.

Activate Loop Detector

This command activates/deactivates the Loop Detectors. Note 
–  the  factory  setting  of  this  function  is  “active”.  For  example, 
if this function is active, if a car is over the loop detector, the 
control unit activates the application to execute an Opening ma-
noeuvre. Input configured as normally open.

Deactivate Loop Detector

This command deactivates the “activate loop detector” mode 
described above. Input configured as normally open.

Emergency stop

When this command is sent, the control unit immediately stops 
the manoeuvre in progress, and ignores all movement com-
mands. Input configured as normally closed.

Содержание LBar

Страница 1: ...Programmable functions using the Oview programmer MBar LBar STF XBA3 Rev00 Firmware XB02a XU01 XF01 ...

Страница 2: ... a programming session followed by the log out procedure on completion of the programming procedure Note the log out procedure enables the user to prevent access by unauthorised personnel by re activating the existing password Caution In programming the password on multiple devices for example on the Oview control unit receiver etc it is advisable to use the same password for all devices including...

Страница 3: ... at the end of the wait time programmed in the function pause time If the function is not active OFF the Control unit operation mode is semiautomatic Pause time 0x81 This parameter is expressed in seconds and can be set with a value from 0 to 250 sec the factory setting is 20 sec This function enables programming on the Control unit of the required wait time which must pass between the end of an O...

Страница 4: ...n of barrier The function enables control of the force absorbed by the motor during a Closing manoeuvre Important Setting this value too high can damage the gearmotor and overheat the control unit closing deceleration force 0x4d This parameter can be set with a value from 10 to 100 the factory setting depends on the version of barrier The function enables control of the maximum force absorbed by t...

Страница 5: ...n be set with a value from 0 to 10 sec the factory setting is 3 sec This function programs the flashing time which indicates the imminent start of a Closing manoeuvre it is associated with the pre flashing function Stand by 0x8b active 0x8c This parameter is ON OFF the factory setting is OFF When this function is set to ON automation power consumption can be reduced mode 0x8e The function has 3 op...

Страница 6: ...ration opening mode This command is factory assigned to Input 2 in mode open When this command is sent the control unit activates the ap plication to complete the Opening manoeuvre until the position is reached as set in the function opening Control unit func tions installation positions opening Input configured as normally open Close Closure Program the desired mode from those listed in table 1 B...

Страница 7: ...de apartment block 1 open When this command is sent the control unit activates the ap plication to perform the opening manoeuvre only until the limit switch is reached Note This command is useful when using control photocells or a magnetic detector loop Input configured as normally open Photo Safety function Photo Program the desired mode from those listed in Table 1 F command configuration photo ...

Страница 8: ...iation of the metal body required to start a manoeuvre Note set a high sensitivity to detect small metal bodies set a low sensitivity to detect large metal bodies Loop activation 0xe7 This parameter type is ON OFF the factory setting is ON Activating the loop means that the barrier will react as programmed when it is tripped If the function is DEACTIVATED the status of the loop is available if one...

Страница 9: ...er command is sent after this one the application executes the Closing manoeuvre with the same sequence Apartment block 2 step by step This executes the sequence close stop partial open 1 partial open 1 until the position is reached as pro grammed in the function Partial Open 1 Note If another command is sent after this one the application executes the Closing manoeuvre with the same sequence Impo...

Страница 10: ...lication to perform a brief inversion in the opposite direction Closing Caution During execution of the Opening manoeuvre this command is ignored Stop When the control unit receives the command it stops the Opening manoeuvre in progress Caution During execu tion of the Opening manoeuvre this command is ignored temporary stop When the control unit receives the command it stops the Closing manoeuvre...

Страница 11: ...er TABLE 2 OUTPUT CONFIGURATION FUNCTION DESCRIPTION sca 0x01 The programmed light indicates the operating status of the control unit light off application in maximum Closing position slow flashing application Opening manoeuvre execution phase quick flashing application Closing manoeuvre execution phase light permanently on application in maximum Opening position SCA1 0x14 The programmed light ind...

Страница 12: ...nnel is not free on the control unit s receiver due to having been previously memorised with a command when the chan nel is activated by the transmitter the control unit only activates the programmed output and ignores the motor command Radio channel 4 0x12 When a transmitter sends a command this output is activated This mode is useful if installing external devices for example an auxiliary light ...

Страница 13: ...tem to be controlled with a single transmitter CAUTION If this channel is not free on the control unit s receiver due to having been previously memorised with a command when the channel is activated by the transmitter the control unit only activates the programmed output and ignores the motor command Output active 24 V DC max 10 W radio channel no 2 If this radio channel is set for the configurati...

Страница 14: ... to occupation by a metal body Loop2 Indicates when the loop is activated due to occupation by a metal body BOARD KEYS no 1 Indicates when key 1 is pressed OPEN on the control unit no 2 Indicates when key 2 is pressed STOP on the control unit no 3 Indicates when key 3 is pressed CLOSE on the control unit DIRECTION SELECTION Indicates the status of the direction selector for a manoeuvre INPUT STATU...

Страница 15: ...ata is useful to understand whether the encoder is in an overtravel position i e outside the operating zone of the absolute encoder bluebus device diagnostics This function displays the type operating status and configuration of devices connected ot the Bluebus output These parameters are described in Table 6 TABLE 6 DIAGNOSTICS of bluebus devices PARAMETER DESCRIPTION Bluebus PHOTOCELLS PHOTO Ind...

Страница 16: ...s required after performing mainte nance on the automation ADVANCED FUNCTIONS event log This function enables the display of the events generated or received by the control unit An event is a condition which changes the operating status of the control unit such as activation of an input end of a manoeuvre photocell or stop input tripped etc This section displays the date and type of an event firmw...

Отзывы: