stop and brief inversion
When the control unit receives the “stop” command, it stops the manoeuvre in progress and activates the applica-
tion to perform a brief inversion in the opposite direction.
Photo
In this category, you can choose one of the operating modes listed in table 1-F.
TABLE 1-F: COMMAND CONFIGURATION
MODE
DESCRIPTION
stop and inversion
Operating mode set in factory. When the control unit receives the command, it stops the Closing manoeuvre in
progress and activates a total inversion (Opening). Caution! – During execution of the Opening manoeuvre, this
command is ignored.
stop and brief inversion
When the control unit receives the command, it stops the Closing manoeuvre in progress and activates the appli-
cation to perform a brief inversion in the opposite direction (Opening). Caution! – During execution of the Opening
manoeuvre, this command is ignored.
Stop
When the control unit receives the command is stop the current Close manoeuvre. Caution! – During execution of
the Opening manoeuvre, this command is ignored.
temporary stop
When the control unit receives the command, it stops the Closing manoeuvre for the entire time that the command
remains active. Otherwise, when the command is no longer active, the control unit activates the application to
perform an Opening manoeuvre. Caution! – During execution of the Opening manoeuvre, this command is ignored.
Temporary stop 2 (0x1c)
When the control unit receives the command, it stops the Closing manoeuvre for as long as the command remains
active. When the command is no longer active, the control unit resumes the Closing manoeuvre from where it pre-
viously stopped it.
– During execution of the Opening manoeuvre, this command is ignored.
Photo 2
In this category, you can choose one of the modes listed in table 1-H.
TABLE 1-H: COMMAND CONFIGURATION
MODE
DESCRIPTION
stop and inversion
Operating mode set in factory. When the control unit receives the command, it stops the Opening manoeuvre in
progress and activates a total inversion (Closing). Caution! – During execution of the Opening manoeuvre, this com-
mand is ignored.
stop and brief inversion
When the control unit receives the command, it stops the Opening manoeuvre in progress and activates the ap-
plication to perform a brief inversion in the opposite direction (Closing). Caution! – During execution of the Opening
manoeuvre, this command is ignored.
Stop
When the control unit receives the command, it stops the Opening manoeuvre in progress. Caution! – During execu-
tion of the Opening manoeuvre, this command is ignored.
temporary stop
When the control unit receives the command, it stops the Closing manoeuvre for the entire time that the command
remains active. Otherwise, when the command is no longer active, the control unit activates the application to
perform an Opening manoeuvre. Caution! – During execution of the Opening manoeuvre, this command is ignored.
Photo 3
In this category, you can choose one of the modes listed in table 1-I.
TABLE 1-I: COMMAND CONFIGURATION
MODE
DESCRIPTION
temporary stop
Operating mode set in factory. When the control unit receives the command, it stops the Closing manoeuvre for the
entire time that the command remains active. Otherwise, when the command is no longer active, the control unit
activates the application to perform an Opening manoeuvre.
Stop
When the control unit receives the command, it stops the manoeuvre in progress.
Alt in opening
In this category, you can choose one of the modes listed in table 1-L.
TABLE 1-L: COMMAND CONFIGURATION
MODE
DESCRIPTION
Stop
Operating mode set in factory. When this type of function is set, when the control unit receives the command, it
stops the Opening manoeuvre in progress immediately.
Stop and brief inversion
When the control unit receives the command, it stops the Opening manoeuvre in progress immediately and acti-
vates the application to perform a brief inversion in the opposite direction (Closing).
Alt and inversion
Operating mode set in factory. When the control unit receives the command, it stops the Opening manoeuvre in
progress and activates a total inversion (Closing). Caution! – During execution of the Opening manoeuvre, this com-
mand is ignored.
Stop in closure
In this category, you can choose one of the modes listed in table 1-M.
TABLE 1-M: COMMAND CONFIGURATION
MODE
DESCRIPTION
Stop
Operating mode set in factory. When the control unit receives the command, it stops the Closing manoeuvre in
progress.
Stop and brief inversion
When the control unit receives the command, it stops the Closing manoeuvre in progress immediately and activates
the application to perform a brief inversion in the opposite direction (Opening).