TABLE 16
LED LR [E]
Off
On
Series of quick flashes, from
1 to 5
Status
All OK
Memorisation in Mode 1
Memorisation in Mode 2
Action
No radio procedure in progress
This is normal during memorisation in mode 1 which lasts maxi-
mum 10s
This is normal during memorisation in mode 2 which lasts maxi-
mum 10s
LED L2 [F]
Off
On
1 flash per second
2 flashes per second
Status
All OK
All OK
No device has been memorised or an error
has occurred in the memorised devices
Device recognition stage in progress
Action
Sensitivity = light door
Sensitivity = heavy door
There may be faulty devices; check and, if necessary, try repeat-
ing the recognition process (see paragraph 3.5.1 “Recognition of
Connected Devices”).
It indicates that the search for the connected devices is underway
LED L3 [G]
Off
On
1 flash per second
2 flashes per second
Status
All OK
All OK
The positions have not been acquired.
Position recognition procedure in progress
Action
Automatic closing deactivated
Automatic closing active
Repeat the position recognition procedure again (see paragraph
3.5.2. “Recognition of the door’s open and closed positions”)